ArticleHernia : the journal of hernias and abdominal wall surgery2019
Telescopic dissection versus balloon dissection for laparoscopic totally extraperitoneal inguinal hernia repair (TEP): a registry-based randomized controlled trial.
Article in Hernia : the journal of hernias and abdominal wall surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03276871 (Randomized Controlled Trial Comparing Telescopic Dissection vs. Balloon Dissection During Laparoscopic TEP Inguinal Hernia Repair), which is not on this map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Randomized Controlled Trial Comparing Telescopic Dissection vs. Balloon Dissection During Laparoscopic TEP Inguinal Hernia Repair
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 21 citations in OpenAlex.
- Balloon dissection versus telescopic dissection during laparoscopic totally extraperitoneal (TEP) inguinal hernia repair: a systematic review, meta-analysis, and trial sequential analysis.Hernia : the journal of hernias and abdominal wall surgery · 2023Pooled it
- Comparison of balloon dissection and telescopic dissection of the preperitoneal space in laparoscopic totally extraperitoneal hernia repair: a systematic review and meta-analysis.Langenbeck's archives of surgery · 2023Pooled it
- Beyond acronyms: a domain-based structural analysis of abdominal wall hernia repair techniques in the contemporary literature.Surgical endoscopy · 2026Article
- How Reproducible Are Abdominal Wall Surgical Techniques? A Methodological Assessment of Technical Reporting in the Contemporary Literature.Journal of abdominal wall surgery : JAWS · 2026Article
- Telescopic dissection versus balloon dissection during laparoscopic totally extraperitoneal inguinal hernia repair: A prospective randomised control trial.Journal of minimal access surgery · 2025Article
- Use cases of registry-based randomized controlled trials-A review of the registries' contributions and constraints.Clinical and translational science · 2024Review
- Prevention and management of intraoperative complication during single incision laparoscopic totally extraperitoneal repair.Journal of minimally invasive surgery · 2022Article
- A totally extraperitoneal approach for endoscopic resection of a congenital prepubic sinus through the pubic symphysis.Surgical case reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 1 country.
Funding
Abstract
objectiveLaparoscopic totally extraperitoneal inguinal hernia repair (TEP) can be performed using either telescopic (TD) or balloon dissection (BD). The use of a disposable balloon dissector increases the cost of TEP. However, it remains unclear whether BD saves enough time to justify its cost. We hypothesized that BD would consistently save 15 min in operative time. To test this hypothesis, we designed a registry-based randomized controlled trial (RB-RCT) embedded into the Americas Hernia Society Quality Collaborative.
methodsA single-blinded, parallel, RB-RCT was conducted. Adults with inguinal hernias presenting for elective repair were screened. Patients with unilateral hernias deemed fit to undergo TEP were eligible; those with bilateral hernias (BIH) or undergoing open repair were excluded. Individuals were randomized to TD or BD with a disposable device. TEP was performed with synthetic mesh and tacks. Subjects were blinded and followed up for 30 day. Main outcome was operative time.
results207 patients were screened: 166 were excluded and 41 were randomized (21 BD, 20 TD). One patient (TD group) was excluded due to the incidental finding of BIH. 40 patients were analyzed (median age 56, median BMI 26 kg/m
conclusionsBD does not consistently result in 15-min time saving during TEP. Use of a disposable balloon dissector can be deferred in the experienced hands.
trial registrationClinicalTrials.gov (NCT03276871).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials