Evidence map›Paper›PMID 31385011›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2019

Triple-gated motion and blood pool clearance corrections improve reproducibility of coronary

Martin Lyngby Lassen, Jacek Kwiecinski, Damini Dey, Sebastien Cadet, Guido Germano, Daniel S Berman, Philip D Adamson, Alastair J Moss, Marc R Dweck, David E Newby and 1 more

Abstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed.

  1. Head-to-head comparison ofJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2024
    Trial
  2. Coronary artery disease imaging with total-body PET.The British journal of radiology · 2026
    Review
  3. From incidental positron emission uptake toFrontiers in cardiovascular medicine · 2026
    Review
  4. Review
  5. Myocardial creep and cardiorespiratory motion correction improves diagnostic accuracy of Rubidium-82 cardiac positron emission tomography.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  6. Article
  7. Review
  8. Advanced Cardiac Imaging in the Assessment of Aortic Stenosis.Journal of cardiovascular development and disease · 2023
    Review
  9. AorticJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  10. Hot spot imaging in cardiovascular diseases: an information statement from SNMMI, ASNC, and EANM.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  11. Review
  12. Article
  13. Effect of respiratory motion correction and CT-based attenuation correction on dual-gated cardiac PET image quality and quantification.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  14. Review
  15. Thoracic AorticJACC. Cardiovascular imaging · 2022
    Observational
  16. Article
  17. Respiration-averaged CT versus standard CT attenuation map for correction ofJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  18. Observer repeatability and interscan reproducibility of 18F-sodium fluoride coronary microcalcification activity.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  19. Aortic valve imaging usingEJNMMI physics · 2022
    Article
  20. Machine Learning withJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Martin Lyngby LassenArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA.
Jacek KwiecinskiArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA.
Damini DeyArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA.
Sebastien CadetArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA.
Guido GermanoArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA.
Daniel S BermanArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA.
Philip D AdamsonBritish Heart Foundation Centre for Cardiovascular Science, Clinical Research Imaging Centre, Edinburgh Heart Centre, University of Edinburgh, Edinburgh, UK.
Alastair J MossBritish Heart Foundation Centre for Cardiovascular Science, Clinical Research Imaging Centre, Edinburgh Heart Centre, University of Edinburgh, Edinburgh, UK.
Marc R DweckBritish Heart Foundation Centre for Cardiovascular Science, Clinical Research Imaging Centre, Edinburgh Heart Centre, University of Edinburgh, Edinburgh, UK.
David E NewbyBritish Heart Foundation Centre for Cardiovascular Science, Clinical Research Imaging Centre, Edinburgh Heart Centre, University of Edinburgh, Edinburgh, UK.
Piotr J SlomkaArtificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, 8700 Beverly Blvd Ste A047N, California, Los Angeles, 90048, USA. piotr.slomka@cshs.org.ORCID http://orcid.org/0000-0002-6110-938X

Funding

Integrated analysis of coronary anatomy and biology with 18F-fluoride PET and CT angiographyR01HL135557 · NHLBI · CEDARS-SINAI MEDICAL CENTER · PI SLOMKA, PIOTR J · 2017 to 2020
$3.0M
British Heart Foundation CH/09/002/26360British Heart Foundation RG/16/10/32375Medical Research Council G0701127NHLBI NIH HHS R01 HL135557NHLBI NIH HHS R01HL135557Wellcome Trust
6 · The paper itself

Abstract

purposeTo improve the test-retest reproducibility of coronary plaque

methodsWe recruited 20 patients with coronary artery disease who underwent repeated hybrid PET/CT angiography (CTA) imaging within 3 weeks. All patients had 30-min PET acquisition and CTA during a single imaging session. Five PET image-sets with progressive motion correction were reconstructed: (i) a static dataset (no-MC), (ii) end-diastolic PET (standard), (iii) cardiac motion corrected (MC), (iv) combined cardiac and gross patient motion corrected (2 × MC) and, (v) cardiorespiratory and gross patient motion corrected (3 × MC). In addition to motion correction, all datasets were corrected for variations in the background activities which are introduced by variations in the injection-to-scan delays (background blood pool clearance correction, BC). Test-retest reproducibility of PET target-to-background ratio (TBR) was assessed by Bland-Altman analysis and coefficient of reproducibility.

resultsA total of 47 unique coronary lesions were identified on CTA. Motion correction in combination with BC improved the PET TBR test-retest reproducibility for all lesions (coefficient of reproducibility: standard = 0.437, no-MC = 0.345 (27% improvement), standard + BC = 0.365 (20% improvement), no-MC + BC = 0.341 (27% improvement), MC + BC = 0.288 (52% improvement), 2 × MC + BC = 0.278 (57% improvement) and 3 × C + BC = 0.254 (72% improvement), all p < 0.001). Importantly, in a sub-analysis of

conclusionJoint corrections for cardiac, respiratory, and gross patient motion in combination with background blood pool corrections markedly improve test-retest reproducibility of coronary

Indexed as

Fluorine RadioisotopesGated Blood-Pool ImagingMovementPositron Emission Tomography Computed TomographySodium FluorideAgedAngiographyCoronary Artery DiseaseFemaleHumansImage Processing, Computer-AssistedMaleReproducibility of ResultsFluorine-18Fluorine RadioisotopesSodium Fluoride18F-sodium fluorideCardiac PETData-driven motion detectionMotion correctionPET/CTVulnerable plaque

Identifiers

PMID31385011
PMCPMC6814554

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.