Evidence map›Paper›PMID 31382707›Full record

ArticleSensors (Basel, Switzerland)2019

Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device.

Pei-Yu Chiang, Paul C-P Chao, Tse-Yi Tu, Yung-Hua Kao, Chih-Yu Yang, Der-Cherng Tarng, Chin-Long Wey

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Machine learning: a new era for cardiovascular pregnancy physiology and cardio-obstetrics research.American journal of physiology. Heart and circulatory physiology · 2024
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Pei-Yu ChiangInstitute of Electrical Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan.
Paul C-P ChaoInstitute of Electrical Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan. pchao@mail.nctu.edu.tw.
Tse-Yi TuInstitute of Electrical Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan.
Yung-Hua KaoDepartment of Electrical Engineering, National Chiao Tung University, Hsinchu 300, Taiwan.
Chih-Yu YangDivision of Nephrology in Taipei Veterans General Hospital, Taipei 11217, Taiwan.
Der-Cherng TarngDivision of Nephrology in Taipei Veterans General Hospital, Taipei 11217, Taiwan.
Chin-Long WeyDepartment of Electrical Engineering, National Chiao Tung University, Hsinchu 300, Taiwan.
National Yang Ming Chiao Tung University · TWTaipei Veterans General Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The classifier of support vector machine (SVM) learning for assessing the quality of arteriovenous fistulae (AVFs) in hemodialysis (HD) patients using a new photoplethysmography (PPG) sensor device is presented in this work. In clinical practice, there are two important indices for assessing the quality of AVF: the blood flow volume (BFV) and the degree of stenosis (DOS). In hospitals, the BFV and DOS of AVFs are nowadays assessed using an ultrasound Doppler machine, which is bulky, expensive, hard to use, and time consuming. In this study, a newly-developed PPG sensor device was utilized to provide patients and doctors with an inexpensive and small-sized solution for ubiquitous AVF assessment. The readout in this sensor was custom-designed to increase the signal-to-noise ratio (SNR) and reduce the environment interference via maximizing successfully the full dynamic range of measured PPG entering an analog-digital converter (ADC) and effective filtering techniques. With quality PPG measurements obtained, machine learning classifiers including SVM were adopted to assess AVF quality, where the input features are determined based on optical Beer-Lambert's law and hemodynamic model, to ensure all the necessary features are considered. Finally, the clinical experiment results showed that the proposed PPG sensor device successfully achieved an accuracy of 87.84% based on SVM analysis in assessing DOS at AVF, while an accuracy of 88.61% was achieved for assessing BFV at AVF.

Indexed as

Machine LearningArteriovenous FistulaConstriction, PathologicHemodynamicsHumansKidney Failure, ChronicPhotoplethysmographyRegional Blood FlowSignal-To-Noise Ratioarteriovenous fistula (AVF)hemodialysis (HD) patientsmachine learning classifiersphotoplethysmography (PPG) sensorsupport vector machine (SVM)

Identifiers

PMID31382707
PMCPMC6695851
OpenAlexW2964942337

What OpenQuestion holds