ArticleFrontiers in oncology2019
Brain and Head-and-Neck MRI in Immobilization Mask: A Practical Solution for MR-Only Radiotherapy.
Article in Frontiers in oncology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.
- Quality requirements for MRI simulation in cranial stereotactic radiotherapy: a guideline from the German Taskforce "Imaging in Stereotactic Radiotherapy".Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024Guideline
- Effect of fractionated therapeutic radiotherapy on surface microhardness and roughness of giomer- and ormocer-based restorative composites: an in vitro study.Scientific reports · 2026Article
- The role of diffusion-weighted MRI in biological image-guided radiation therapy: a roadmap.Physics in medicine and biology · 2026Review
- Article
- AAPM Task Group 334: A guidance document to using radiotherapy immobilization devices and accessories in an MR environment.Medical physics · 2024Article
- Commissioning, clinical implementation, and initial experience with a new brain tumor treatment package on a low-field MR-linac.Journal of applied clinical medical physics · 2023Article
- 3D T1-weighted turbo spin echo contrast-enhanced MRI at 1.5 T for frameless brain metastases radiotherapy.Journal of cancer research and clinical oncology · 2022Article
- Patient positioning and immobilization procedures for hybrid MR-Linac systems.Radiation oncology (London, England) · 2021Review
- Comparison of treatment position with mask immobilization and standard diagnostic setup in intracranial MRI radiotherapy simulation.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2021Article
- Implementation of a dedicated 1.5 T MR scanner for radiotherapy treatment planning featuring a novel high-channel coil setup for brain imaging in treatment position.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2021Article
- Magnetic resonance imaging for brain stereotactic radiotherapy : A review of requirements and pitfalls.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In brain/head-and-neck radiotherapy (RT), thermoplastic immobilization masks guarantee reproducible patient positioning in treatment position between MRI, CT, and irradiation. Since immobilization masks do not fit in the diagnostic MR head/head-and-neck coils, flexible surface coils are used for MRI imaging in clinical practice. These coils are placed around the head/neck, in contact with the immobilization masks. However, the positioning of these flexible coils is technician dependent, thus leading to poor image reproducibility. Additionally, flexible surface coils have an inferior signal-to-noise-ratio (SNR) compared to diagnostic coils. The aim of this work was to create a new immobilization setup which fits into the diagnostic MR coils in order to enhance MR image quality and reproducibility. For this purpose, a practical immobilization setup was constructed. The performances of the standard clinical and the proposed setups were compared with four tests: SNR, image quality, motion restriction, and reproducibility of inter-fraction subject positioning. The new immobilization setup resulted in 3.4 times higher SNR values on average than the standard setup, except directly below the flexible surface coils where similar SNR was observed. Overall, the image quality was superior for brain/head-and-neck images acquired with the proposed RT setup. Comparable motion restriction in feet-head/left-right directions (maximum motion ≈1 mm) and comparable inter-fraction repositioning accuracy (mean inter-fraction movement 1 ± 0.5 mm) were observed for the standard and the new setup.