Evidence map›Paper›PMID 31380204›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2019

Investigation of Low-Current Direct Stimulation for Rehabilitation Treatment Related to Muscle Function Loss Using Self-Powered TENG System.

Jiahui Wang, Hao Wang, Tianyiyi He, Borong He, Nitish V Thakor, Chengkuo Lee

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Wearable Bioelectronics for Home-Based Monitoring and Treatment of Muscle Atrophy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  6. Article
  7. Article
  8. Implantable Self-Powered Systems for Electrical Stimulation Medical Devices.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  9. Study on Recovery Strategy of Hearing Loss & SGN Regeneration Under Physical Regulation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Review
  17. Review
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiahui WangDepartment of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.
Hao WangDepartment of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.
Tianyiyi HeDepartment of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.
Borong HeDepartment of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.
Nitish V ThakorDepartment of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.
Chengkuo LeeDepartment of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.ORCID https://orcid.org/0000-0002-8886-3649

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Muscle function loss is characterized as abnormal or completely lost muscle capabilities, and it can result from neurological disorders or nerve injuries. The currently available clinical treatment is to electrically stimulate the diseased muscles. Here, a self-powered system of a stacked-layer triboelectric nanogenerator (TENG) and a multiple-channel epimysial electrode to directly stimulate muscles is demonstrated. Then, the two challenges regarding direct TENG muscle stimulation are further investigated. For the first challenge of improving low-current TENG stimulation efficiency, it is found that the optimum stimulation efficiency can be achieved by conducting a systematic mapping with a multiple-channel epimysial electrode. The second challenge is TENG stimulation stability. It is found that the force output generated by TENGs is more stable than using the conventional square wave stimulation and enveloped high frequency stimulation. With modelling and in vivo measurements, it is confirmed that the two factors that account for the stable stimulation using TENGs are the long pulse duration and low current amplitude. The current waveform of TENGs can effectively avoid synchronous motoneuron recruitment at the two stimulation electrodes to reduce force fluctuation. Here, after investigating these two challenges, it is believed that TENG direct muscle stimulation could be used for rehabilitative and therapeutic purpose of muscle function loss treatment.

Indexed as

electrical muscle stimulationself‐poweredstimulation efficiencystimulation stabilitystimulation waveformtriboelectric direct stimulation

Identifiers

PMID31380204
PMCPMC6662055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.