Evidence map›Paper›PMID 31377964›Full record

ArticleInternational journal of computer assisted radiology and surgery2019

Pitfalls in interventional X-ray organ dose assessment-combined experimental and computational phantom study: application to prostatic artery embolization.

Philipp Roser, Annette Birkhold, Xia Zhong, Philipp Ochs, Elizaveta Stepina, Markus Kowarschik, Rebecca Fahrig, Andreas Maier

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. XDose: toward online cross-validation of experimental and computational X-ray dose estimation.International journal of computer assisted radiology and surgery · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Philipp RoserPattern Recognition Lab, FAU Erlangen-Nürnberg, Erlangen, Germany. philipp.roser@fau.de.
Annette BirkholdSiemens Healthcare GmbH, Forchheim, Germany.
Xia ZhongPattern Recognition Lab, FAU Erlangen-Nürnberg, Erlangen, Germany.
Philipp OchsSiemens Healthcare GmbH, Forchheim, Germany.
Elizaveta StepinaSiemens Healthcare GmbH, Forchheim, Germany.
Markus KowarschikSiemens Healthcare GmbH, Forchheim, Germany.
Rebecca FahrigSiemens Healthcare GmbH, Forchheim, Germany.
Andreas MaierPattern Recognition Lab, FAU Erlangen-Nürnberg, Erlangen, Germany.
Siemens Healthcare (Germany) · DEFriedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWith X-ray radiation protection and dose management constantly gaining interest in interventional radiology, novel procedures often undergo prospective dose studies using anthropomorphic phantoms to determine expected reference organ-equivalent dose values. Due to inherent uncertainties, such as impact of exact patient positioning, generalized geometry of the phantoms, limited dosimeter positioning options, and composition of tissue-equivalent materials, these dose values might not allow for patient-specific risk assessment. Therefore, first the aim of this study is to quantify the influence of these parameters on local X-ray dose to evaluate their relevance in the assessment of patient-specific organ doses. Second, this knowledge further enables validating a simulation approach, which allows employing physiological material models and patient-specific geometries.

methodsPhantom dosimetry experiments using MOSFET dosimeters were conducted reproducing imaging scenarios in prostatic arterial embolization (PAE). Associated organ-equivalent dose of prostate, bladder, colon, and skin was determined. Dose deviation induced by possible small displacements of the patient was reproduced by moving the X-ray source. Dose deviation induced by geometric and material differences was investigated by analyzing two different commonly used phantoms. We reconstructed the experiments using Monte Carlo (MC) simulations, a reference male geometry, and different material properties to validate simulations and experiments against each other.

resultsOverall, MC-simulated organ dose values are in accordance with the measured ones for the majority of cases. Marginal displacements of X-ray source relative to the phantoms lead to deviations of 6-135% in organ dose values, while skin dose remains relatively constant. Regarding the impact of phantom material composition, underestimation of internal organ dose values by 12-20% is prevalent in all simulated phantoms. Skin dose, however, can be estimated with low deviation of 1-8% at least for two materials.

conclusionsProspective reference dose studies might not extend to precise patient-specific dose assessment. Therefore, online organ dose assessment tools, based on advanced patient modeling and MC methods, are desirable.

Indexed as

Phantoms, ImagingAdultDose-Response Relationship, RadiationEmbolization, TherapeuticHumansMaleMonte Carlo MethodProspective StudiesProstateProstatic HyperplasiaRadiation DosageRadiography, InterventionalRadiometryAnthropomorphic phantomDosimetryMonte Carlo simulationMOSFETProstatic artery embolization

Identifiers

PMID31377964
OpenAlexW2965343553

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.