Evidence map›Paper›PMID 31375297›Full record

ArticleMedical dosimetry : official journal of the American Association of Medical Dosimetrists

The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients.

Jussi Sillanpaa, Michael Lovelock, Boris Mueller

Abstract read
In one paragraph

Article in Medical dosimetry : official journal of the American Association of Medical Dosimetrists. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jussi SillanpaaDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NJ 07748, USA. Electronic address: jussinyc@gmail.com.
Michael LovelockDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NJ 07748, USA.
Boris MuellerDepartment of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NJ 07748, USA.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

Metallic objects, such as dental fillings, cause artifacts in computed tomography (CT) scans. We quantify the contouring and dosimetric effects of Orthopedic Metal Artifact Reduction (O-MAR), in head and neck radiotherapy. The ease of organ contouring was assessed by having a radiation oncologist identify the CT data set with or without O-MAR for each of 28 patients that was easier to contour. The effect on contouring was quantified further by having the physician recontour parotid glands, previously drawn by him on the O-MAR scans, on uncorrected scans, and calculating the Dice coefficent (a measure of overlap) for the contours. Radiotherapy plans originally generated on scans reconstructed with O-MAR were recalculated on scans without metal artifact correction. The study was done using the Analytical Anisotropic Algorithm (AAA) dose calculation algorithm. The 15 patients with a planning target volume (PTV) extending to the same slice as the artifacts were used for this part of the study. The normal tissue doses were not significantly affected. The PTV mean dose and V95 were not affected, but the cold spots became less severe in the O-MAR corrected plans, with the minimum point dose on average being 4.1% higher. In 79% of the cases, the radiation oncologist identified the O-MAR scan as easier to contour; in 11% he chose the uncorrected scan and in 11% the scans were judged to have equal quality. A total of nine parotid glands (on both scans-18 contours in total) in 5 patients were recontoured. The average Dice coefficient for parotids drawn with and without O-MAR was found to be 0.775 +/- 0.045. The O-MAR algorithm does not produce a significant dosimetric effect in head and neck plans when using the AAA dose calculation algorithm. It can therefore be used for improved contouring accuracy without updating the critical structure tolerance doses and target coverage expectations.

Indexed as

AlgorithmsArtifactsHead and Neck NeoplasmsHumansMetalsOrthopedic Fixation DevicesRadiotherapy DosageRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedMetalsHead and neck cancerIMRTMetal artifact correctionTreatment planning

Identifiers

PMID31375297
PMCPMC6989373

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.