Evidence map›Paper›PMID 31374747›Full record

ArticleIEEE ... International Conference on Rehabilitation Robotics : [proceedings]2019

Design and Validation of a Partial-Assist Knee Orthosis with Compact, Backdrivable Actuation.

Hanqi Zhu, Christopher Nesler, Nikhil Divekar, M Taha Ahmad, Robert D Gregg

Open access · greenAbstract readValidation Study
In one paragraph

Article in IEEE ... International Conference on Rehabilitation Robotics : [proceedings], 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Modeling and Stiffness-based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2022
    Article
  3. Article
  4. Effects of a Powered Knee-Ankle Prosthesis on Amputee Hip Compensations: A Case Series.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2020
    Article
  5. Design and Validation of a Powered Knee-Ankle Prosthesis with High-Torque, Low-Impedance Actuators.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2020
    Article
  6. Quasi-Direct Drive Actuation for a Lightweight Hip Exoskeleton with High Backdrivability and High Bandwidth.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Hanqi Zhu
Christopher Nesler
Nikhil Divekar
M Taha Ahmad
Robert D Gregg
The University of Texas at Dallas · US

Funding

PHASE-BASED CONTROL OF LOCOMOTION FOR HIGH-PERFORMANCE PROSTHESES AND ORTHOSESDP2HD080349 · NICHD · UNIVERSITY OF TEXAS DALLAS · PI GREGG, ROBERT D · 2013 to 2013
$2.3M
NICHD NIH HHS DP2 HD080349
6 · The paper itself

Abstract

This paper presents the mechatronic design and initial validation of a partial-assist knee orthosis for individuals with musculoskeletal disorders, e.g., knee osteoarthritis and lower back pain. This orthosis utilizes a quasi-direct drive actuator with a low-ratio transmission (7:1) to greatly reduce the reflected inertia for high backdrivability. To provide meaningful assistance, a custom Brushless DC (BLDC) motor is designed with encapsulated windings to improve the motor's thermal environment and thus its continuous torque output. The 2.69 kg orthosis is constructed from all custom-made components with a high package factor for lighter weight and a more compact size. The combination of compactness, backdrivability, and torque output enables the orthosis to provide partial assistance without obstructing the natural movement of the user. Several benchtop tests verify the actuator's capabilities, and a human subject experiment demonstrates reduced quadriceps muscle activation when assisted during a repetitive lifting and lowering task.

Indexed as

Orthotic DevicesProsthesis DesignElectromyographyHumansKneeMagnetic FieldsMaleTemperatureTorque

Identifiers

PMID31374747
PMCPMC6684309
OpenAlexW2964622555

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.