Evidence map›Paper›PMID 31372760›Full record

ArticlePediatric nephrology (Berlin, Germany)2020

Serial measurement of electrolyte and citrate concentrations in blood-primed continuous hemodialysis circuits during closed-circuit dialysis.

Daisuke Saito, Takuya Fujimaru, Yoshihiro Inoue, Tomoyuki Hirayama, Itaru Ezaki, Hassu Kin, Takuya Shuo, Masaaki Nakayama, Yasuhiro Komatsu

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric nephrology (Berlin, Germany), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 87% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Neonatal continuous kidney replacement therapy.Pediatric nephrology (Berlin, Germany) · 2026
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Daisuke SaitoDepartment of Clinical Engineering, St. Luke's International Hospital, Tokyo, Japan.
Takuya FujimaruDepartment of Nephrology, St. Luke's International Hospital, 9-1 Akashi-cho, Chuo-ku, Tokyo, 104-8560, Japan. t.fujimaru1217@gmail.com.ORCID 0000-0002-6825-3456
Yoshihiro InoueDepartment of Clinical Engineering, St. Luke's International Hospital, Tokyo, Japan.
Tomoyuki HirayamaDepartment of Clinical Engineering, St. Luke's International Hospital, Tokyo, Japan.
Itaru EzakiDepartment of Clinical Engineering, St. Luke's International Hospital, Tokyo, Japan.
Hassu KinDepartment of Clinical Engineering, St. Luke's International Hospital, Tokyo, Japan.
Takuya ShuoFaculty of Pharmaceutical Sciences, Hokuriku University, Kanazawa, Ishikawa, Japan.
Masaaki NakayamaDepartment of Nephrology, St. Luke's International Hospital, 9-1 Akashi-cho, Chuo-ku, Tokyo, 104-8560, Japan.
Yasuhiro KomatsuDepartment of Nephrology, St. Luke's International Hospital, 9-1 Akashi-cho, Chuo-ku, Tokyo, 104-8560, Japan.
St. Luke's International Hospital · JPGunma University · JPHokuriku University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFor continuous renal replacement therapy in small infants, due to the large extracorporeal volume involved, blood priming can be necessary to prevent hypotension and hemodilution. Because packed red blood cells (RBCs) have high levels of potassium and citrate, closed-circuit dialysis is often performed. We assessed the metrics of closed-circuit dialysis and serial citrate concentration changes.

methodsWe performed dialysis of closed circuits primed with expired human packed RBC solution and 5% albumin. Blood and dialysate flow rates were 70 and 33.3 mL/min, respectively. The extracorporeal volume was 70 mL. We measured pH, electrolytes, and citrate in the closed circuit every 3 min for 15 min. We also assessed the adequacy of closed-circuit dialysis using the formula: [dialysate flow rate (mL/min) × time of dialysis (min)]/extracorporeal volume (mL) and we assessed the correlation between citrate and ionized calcium concentrations.

resultsTo reach normal concentrations of sodium, potassium, and chloride, 2.4 times as much dialysate fluid as extracorporeal volume was needed. In contrast, for ionized calcium, bicarbonate, and citrate, 3.8 times as much dialysate fluid as extracorporeal volume was required. By simple linear regression analysis, the concentration of citrate was significantly correlated with that of ionized calcium.

conclusionsFor closed-circuit dialysis using an RBC solution, the formula [dialysate flow rate (mL/min) × time of dialysis (min)]/extracorporeal volume (mL) would be a better parameter to estimate efficacy, compared with other metrics. Additionally, the citrate concentration can be readily estimated from the ionized calcium concentration during closed-circuit dialysis.

Indexed as

CalciumChloridesCitric AcidCritical IllnessDialysis SolutionsElectrolytesErythrocyte TransfusionHumansInfantKidney DiseasesLongitudinal StudiesPotassiumRenal DialysisSeverity of Illness IndexSodiumCalciumChloridesCitric AcidDialysis SolutionsElectrolytesPotassiumSodiumBlood primeChildrenCitrateClosed-circuit dialysisContinuous renal replacement therapy

Identifiers

PMID31372760
OpenAlexW2966801300

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.