Evidence map›Paper›PMID 31372187›Full record

ArticleCellular and molecular bioengineering2018

Effects of Transient Exposure to High Shear on Neutrophil Rolling Behavior.

Christopher S Lewis, Nesreen Z Alsmadi, Trevor A Snyder, David W Schmidtke

Abstract read
In one paragraph

Article in Cellular and molecular bioengineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Production of erythrocyte microparticles in a sub-hemolytic environment.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2021
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christopher S LewisSchool of Chemical, Biological, and Materials Engineering, University of Oklahoma, Norman, OK 73019 USA.
Nesreen Z AlsmadiDepartment of Bioengineering, University of Texas at Dallas, Richardson, TX 75083 USA.
Trevor A SnyderVADovations, Inc., Oklahoma City, OK 73108 USA.
David W SchmidtkeDepartment of Bioengineering, University of Texas at Dallas, Richardson, TX 75083 USA.ORCID 0000-0001-6404-318X

Funding

Development of a Miniature Right Heart Support DeviceR44HL114246 · NHLBI · VADOVATIONS, INC. · PI SNYDER, TREVOR ARNOULT · 2012 to 2014
$3.3M
Altered Neutrophil Function in Ventricular Assist DevicesR21HL132286 · NHLBI · UNIVERSITY OF TEXAS DALLAS · PI SCHMIDTKE, DAVID W · 2016 to 2017
$401k
NHLBI NIH HHS R21 HL132286NHLBI NIH HHS R44 HL114246
6 · The paper itself

Abstract

introductionNeutrophils display an array of behaviors ranging from rolling and migration to phagocytosis and granule secretion. Several of these behaviors are modulated by the local shear conditions. In the normal circulation, neutrophils experience shear rates from approximately 10-2,000 s

methodsWe developed a set of microfluidic devices capable of exposing neutrophils to high shear rates for short durations (100-400 msec). Suspensions of isolated neutrophils were perfused through the devices and their rolling velocities on P-selectin were analyzed before and after shear exposure.

resultsWe observed a significant increase in neutrophil rolling velocities on P-selectin coated regions following transient high shear exposure. The magnitude of the rolling velocity increase was dependent upon the duration of high shear exposure and became statistically significant for exposure times of 310 msec or longer. When polystyrene beads coated with a glycosulfopeptide that mimics the binding region of P-selectin glycoprotein ligand-1 (PSGL-1) were perfused through the devices, no change between the pre-shear and post-shear rolling velocities was observed.

conclusionsThese results suggest that high shear levels alter normal neutrophil rolling behavior and are important for understanding neutrophil biology in high shear conditions, as well as for improving medical device performance.

Indexed as

MicrofluidicsNeutrophilP-selectinRollingShear RateVentricular Assist Device

Identifiers

PMID31372187
PMCPMC6673669

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.