ArticleBMC musculoskeletal disorders2019
Effects of femoral bone defect morphology on initial polished tapered stem stability in massive defect model: a biomechanical study.
Article in BMC musculoskeletal disorders, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
backgroundGood outcomes have been reported in revision total hip replacement with massive segmental defects using impaction bone grafting with circumferential metal meshes. However, the morphology of defects that require a mesh is poorly defined. The purpose of this study was to evaluate the effects of a variety of segmental defects on load transmission to the proximal femur under both axial and rotational loads.
methodsInitial stability of the Exeter stem was investigated in a composite bone model using three medial bone defect morphologies: Long (length 5 cm × width 2 cm), Short (2.5 cm × 2 cm), Square (3.2 cm × 3.2 cm), Square with mesh (3.2 cm × 3.2 cm defect covered with metal mesh), and with no defect as control. Specimens (5 per group) were axially loaded and internally rotated up to 20° or to failure. Strain distributions of the femora were measured using a strain gauge.
resultsAll Square group specimens failed while rotation was increasing. In the other four groups, failure was not observed in any specimens. Mean torsional stiffness in the Long (4.4 ± 0.3 Nm/deg.) and Square groups (4.3 ± 0.3 Nm/deg.) was significantly smaller than in the Control group (4.8 ± 0.3 Nm/deg.). In the medio-cranial region, the magnitude of the maximum principal strain in the Square group (1176.4 ± 100.9) was significantly the largest (Control, 373.2 ± 129.5, p < 0.001; Long, 883.7 ± 153.3, p = 0.027; Short, 434.5 ± 196.8, p < 0.001; Square with mesh, 256.9 ± 100.8, p < 0.001). Torsional stiffness, and both maximum and minimum principal strains in the Short group showed no difference compared to the Control group in any region.
conclusionsBone defect morphology greatly affected initial stem stability and load transmission. If defect morphology is not wide and the distal end is above the lower end of the lesser trochanter, it may be acceptable to fill the bone defect region with bone cement. However, this procedure is not acceptable for defects extending distally below the lower end of the lesser trochanter or defects 3 cm or more in width.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.