Trial reportJapanese journal of ophthalmology2019
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma.
Trial report in Japanese journal of ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Efficacy analysis of microinvasive glaucoma surgery alone or in combination with phacoemulsification in patients with normal tension glaucoma: a systematic review and meta-analysis.BMC ophthalmology · 2025Pooled it
- Glaucoma Ex-PRESS Implantation Surgery: Is There a Difference in Efficacy and Safety between Inpatient and Outpatient Management?JMA journal · 2024Article
- Contributing factors for intraocular pressure control in patients with mostly normal-tension glaucoma after initial Ex-PRESS drainage device implantation.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024Article
- Compared to Trabeculectomy, Ex-PressClinical ophthalmology (Auckland, N.Z.) · 2024Article
- Comparison of the results of Ex-PRESSInternational ophthalmology · 2023Article
- Ex-PRESS® surgery versus trabeculectomy for primary open-angle glaucoma with low preoperative intraocular pressure.International ophthalmology · 2022Article
- Visual cortex damage in a ferret model of ocular hypertension.Japanese journal of ophthalmology · 2022Article
- The effects of antithrombotic therapy in ab interno trabeculotomy with a spatula-shaped microhook.PloS one · 2022Article
- Comparison of 12-month surgical outcomes of ab interno trabeculotomy with phacoemulsification between spatula-shaped and dual-blade microhooks.Japanese journal of ophthalmology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo assess the efficacy and safety of filtration surgery using the EX-PRESS glaucoma filtration device in patients with normal-tension glaucoma (NTG). STUDY
designProspective, single-arm, multicenter interventional case series.
methodsEyes with NTG underwent EX-PRESS implantation with or without cataract surgery. The efficacy and safety were assessed at 1 day; 1 and 2 weeks; and 1, 3, 6, and 12 months after surgery. The main outcome measure was reduction in intraocular pressure (IOP) from baseline at 3, 6, and 12 months after surgery. Safety assessments included adverse event incidence, postoperative inflammation, and corneal endothelial cell density.
resultsThirty-two Japanese patients (37 eyes) with NTG were enrolled. The mean IOP decreased from 14.8 ± 2.3 mmHg at baseline to 10.0 ± 3.1 mmHg at 12 months after surgery (mean reduction 4.9 ± 4.2 mmHg [31.1%]; P < .0001). IOP-lowering medication use decreased from a mean of 3.3 medications per eye before surgery to 0.1 medications per eye at 12 months after surgery. IOP reductions > 20% were achieved by 61.5% of the eyes at 12 months. Adverse events were typical for filtration procedures, and none was deemed device-related. Postoperative inflammation was mild and self-limiting. The mean corneal endothelial cell density had decreased by 3.3% at 12 months after surgery.
conclusionThe EX-PRESS glaucoma filtration device is safe and effective for filtration surgery in patients with NTG, providing mean IOP reduction consistent with recommendations based on the Collaborative NTG Study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials