Evidence map›Paper›PMID 31366278›Full record

ArticleCirculation research2019

Instantaneous Amplitude and Frequency Modulations Detect the Footprint of Rotational Activity and Reveal Stable Driver Regions as Targets for Persistent Atrial Fibrillation Ablation.

Jorge G Quintanilla, José Manuel Alfonso-Almazán, Nicasio Pérez-Castellano, Sandeep V Pandit, José Jalife, Julián Pérez-Villacastín, David Filgueiras-Rama

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in Circulation research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05169320 (Patient-TAILORed Ablation of Atrial Fibrillation Drivers in Persistent Stages Based on Instantaneous Amplitude and Frequency Modulation Criteria), which is not on this map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
2.7field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05169320 unknown statusnot on this mapstarted 2021, after this paper: background citation

Patient-TAILORed Ablation of Atrial Fibrillation Drivers in Persistent Stages Based on Instantaneous Amplitude and Frequency Modulation Criteria (TAILOR-AF)

TypeobservationalSponsorHospital San Carlos, MadridRan2021 to 2024Enrolled25ConditionsPersistent Atrial FibrillationArmsSubcutaneous implantable loop recorder (ILR) implantation, Mapping and catheter ablation, Minimally invasive surgical ablation via thoracoscopy
3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Stretch-Induced Increase in CaJournal of the American Heart Association · 2025
    Article
  8. Review
  9. Article
  10. Isolated Perfused Hearts for Cardiovascular Research: An Old Dog with New Tricks.Journal of cardiovascular translational research · 2024
    Review
  11. Article
  12. Article
  13. Therapeutic advances in atrial fibrillation based on animal models.Journal of Zhejiang University. Science. B · 2024
    Review
  14. Towards Improved HumanBiomedicines · 2023
    Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Jorge G QuintanillaFrom the Myocardial Pathophysiology Area, Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain (J.G.Q., J.M.A.-A., J.J., D.F.-R.).
José Manuel Alfonso-AlmazánFrom the Myocardial Pathophysiology Area, Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain (J.G.Q., J.M.A.-A., J.J., D.F.-R.).
Nicasio Pérez-CastellanoArrhythmia Unit, Cardiology Department, Cardiovascular Institute, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain (J.G.Q., N.P.-C., J.P.-V., D.F.-R.).
Sandeep V PanditCenter for Arrhythmia Research, Department of Internal Medicine, University of Michigan, Ann Arbor (S.V.P., J.J.).
José JalifeFrom the Myocardial Pathophysiology Area, Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain (J.G.Q., J.M.A.-A., J.J., D.F.-R.).
Julián Pérez-VillacastínFrom the Myocardial Pathophysiology Area, Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain (J.G.Q., J.M.A.-A., J.J., D.F.-R.).
David Filgueiras-RamaFrom the Myocardial Pathophysiology Area, Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain (J.G.Q., J.M.A.-A., J.J., D.F.-R.).
Centro de Investigación Biomédica en Red · ESSpanish National Centre for Cardiovascular Research · ESCentro de Investigación en Red en Enfermedades Cardiovasculares · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

rationaleCostly proprietary panoramic multielectrode (64-256) acquisition systems are being increasingly used together with conventional electroanatomical mapping systems for persistent atrial fibrillation (PersAF) ablation. However, such approaches target alleged drivers (rotational/focal) regardless of their activation frequency dynamics.

objectivesTo test the hypothesis that stable regions of higher than surrounding instantaneous frequency modulation (iFM) drive PersAF and determine whether rotational activity is specific for such regions. METHODS AND

resultsFirst, novel single-signal algorithms based on instantaneous amplitude modulation (iAM) and iFM to detect rotational-footprints without panoramic multielectrode acquisition systems were tested in 125 optical movies from 5 ex vivo Langendorff-perfused PersAF sheep hearts (sensitivity/specificity, 92.6/97.5%; accuracy, 2.5-mm) and in computer simulations. Then, 16 pigs underwent high-rate atrial pacing to develop PersAF. After a median (interquartile range [IQR]) of 4.4 (IQR, 2.5-9.9) months of high-rate atrial pacing followed by 4.1 (IQR, 2.7-5.4) months of self-sustained PersAF, pigs underwent in vivo high-density electroanatomical atrial mapping (4920 [IQR, 4435-5855] 8-second unipolar signals per map). The first 4 out of 16 pigs were used to adapt ex vivo optical proccessing of iFM/iAM to in vivo electrical signals. In the remaining 12 out of 16 pigs, regions of higher than surrounding average iFM were considered leading-drivers. Two leading-driver + rotational-footprint maps were generated 2.6 (IQR, 2.4-2.9) hours apart to test leading-driver spatiotemporal stability and guide ablation. Leading-driver regions (2.5 [IQR, 2.0-4.0] regions/map) exactly colocalized (95.7%) in the 2 maps, and their ablation terminated PersAF in 92.3% of procedures (radiofrequency until termination, 16.9 [IQR, 9.2-35.8] minutes; until nonsustainability, 20.4 [IQR, 12.8-44.0] minutes). Rotational-footprints were found at every leading-driver region, albeit most (76.8% [IQR, 70.5%-83.6%]) were located outside. Finally, the translational ability of this approach was tested in 3 PersAF redo patients.

conclusionsBoth rotational-footprints and spatiotemporally stable leading-driver regions can be located using iFM/iAM algorithms without panoramic multielectrode acquisition systems. In pigs, ablation of leading-driver regions usually terminates PersAF and prevents its sustainability. Rotational activations are sensitive but not specific to such regions. Single-signal iFM/iAM algorithms could be integrated into conventional electroanatomical mapping systems to improve driver detection accuracy and reduce the cost of patient-tailored/mechanistic approaches.

Indexed as

Action PotentialsAdultAgedAnimalsAtrial FibrillationBody Surface Potential MappingCatheter AblationFemaleHeart RateHumansImaging, Three-DimensionalIsolated Heart PreparationMaleMiddle AgedSheepSwineablationalgorithmsatrial fibrillationdrivermappingrotor

Identifiers

PMID31366278
PMCPMC6735936
OpenAlexW2965824923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.