Evidence map›Paper›PMID 31366026›Full record

ArticleBiosensors2019

The Presence of Polysaccharides, Glycerol, and Polyethyleneimine in Hydrogel Enhances the Performance of the Glucose Biosensor.

Marco Fois, Paola Arrigo, Andrea Bacciu, Patrizia Monti, Salvatore Marceddu, Gaia Rocchitta, Pier Andrea Serra

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Marco FoisDipartimento di Scienze Mediche, Chirurgiche e Sperimentali, Università degli Studi di Sassari, Viale San Pietro 43/b, 07100 Sassari, Italy.
Paola ArrigoDipartimento di Scienze Mediche, Chirurgiche e Sperimentali, Università degli Studi di Sassari, Viale San Pietro 43/b, 07100 Sassari, Italy.
Andrea BacciuDipartimento di Scienze Mediche, Chirurgiche e Sperimentali, Università degli Studi di Sassari, Viale San Pietro 43/b, 07100 Sassari, Italy.
Patrizia MontiDipartimento di Agraria and Unità di Ricerca Istituto Nazionale di Biostrutture e Biosistemi, Università degli Studi di Sassari, Viale Italia 39, 07100 Sassari, Italy.
Salvatore MarcedduIstituto CNR di Scienze delle Produzioni Alimentari-UOS Sassari, Traversa La Crucca 3, 07100 Sassari, Italy.
Gaia RocchittaDipartimento di Scienze Mediche, Chirurgiche e Sperimentali, Università degli Studi di Sassari, Viale San Pietro 43/b, 07100 Sassari, Italy. grocchitta@uniss.it.ORCID 0000-0002-4319-4197
Pier Andrea SerraDipartimento di Scienze Mediche, Chirurgiche e Sperimentali, Università degli Studi di Sassari, Viale San Pietro 43/b, 07100 Sassari, Italy.
University of Sassari · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of amperometric biosensors has attracted particular attention in recent years, both from researchers and from companies, as they have proven to be low-cost, reliable, and very sensitive devices, with a wide range of uses in different matrices. The continuous development of amperometric biosensors, since their use involves an enzyme, is specifically aimed at keeping and increasing the catalytic properties of the loaded protein, so as to be able to use the same device over time. The present study aimed to investigate the impact of glycerol and polysaccharides, in the presence of polycationic substances to constitute a hydrogel, in enhancing the enzymatic and analytic performance of a glucose biosensor. Initially, it was possible to verify how the deposition of the starch-based hydrogel, in addition to allowing the electropolymerization of the poly(p-phenylenediamine) polymer and the maintenance of its ability to shield the ascorbic acid, did not substantially limit the permeability towards hydrogen peroxide. Moreover, different biosensor designs, loading a mixture containing all the components (alone or in combination) and the enzyme, were tested in order to evaluate the changes of the apparent enzyme kinetic parameters, such as V

Indexed as

Biosensing TechniquesEnzymes, ImmobilizedEnzyme StabilityGlucoseGlycerolHydrogelsKineticsPolyethyleneiminePolysaccharidesTime FactorsEnzymes, ImmobilizedGlucoseGlycerolHydrogelsPolyethyleneiminePolysaccharidesglucose biosensorglycerolpolyethyleneiminestarch-based hydrogel

Identifiers

PMID31366026
PMCPMC6784354
OpenAlexW2966033237

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.