SynthesisEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2019
Comparative outcomes between collared versus collarless and short versus long stem of direct anterior approach total hip arthroplasty: a systematic review and indirect meta-analysis.
Synthesis in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 1 synthesis or guideline pooled it, 35 citations in OpenAlex.
- Long-term survival of CLS Spotorno femoral stem: a systematic review of literature.Archives of orthopaedic and trauma surgery · 2022Pooled it
- Comparison of 5-year postoperative results between standard-length stems and short stems in one-stage bilateral total hip arthroplasty: a randomized controlled trial.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021Trial
- Ten-year migration analysis of a cementless metaphyseal-anchored short femoral stem in total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Article
- Collared Triple Taper Stems Have Superior Biomechanical Characteristics in Compromised Bone.Arthroplasty today · 2026Article
- Article
- Collared Femoral Stems Have Lower Risk of Postoperative PPFs After THA: A Retrospective Cohort Study.Indian journal of orthopaedics · 2026Article
- Fixation Methods in Primary Hip Arthroplasty: A Nationwide, Registry-Based Observational Study in Romania (2001-2024).Healthcare (Basel, Switzerland) · 2025Article
- Impact of stem collar to femoral calcar gap distance on postoperative bone remodeling in a fully hydroxyapatite-coated stem.Scientific reports · 2025Article
- Two-Dimensional Preoperative Digital Templating is Less Accurate When Using a Collared Triple Taper Stem Versus a Single Taper Design.Arthroplasty today · 2025Article
- Radiographic Performance of a Novel Femoral Stem Design.The Iowa orthopaedic journal · 2025Article
- Recognition and Recurrence of Aneurysmal Bone Cyst Secondary to Giant Cell Tumor: A Case Series and Review Of The Literature.The Iowa orthopaedic journal · 2025Review
- Outcomes of total hip arthroplasty using collared versus collarless uncemented HA-coated stems: a meta-analysis.EFORT open reviews · 2024Article
- Slightly reduced early subsidence with similar outcomes and complications rate in collared stems - A systematic review of randomized clinical trials.Journal of orthopaedics · 2024Review
- Article
- No significant differences in 60-day postoperative complication rates between conventional and shortened stems.Journal of experimental orthopaedics · 2023Article
- Article
- Migration Characteristics of a Proximally Coated Collarless Femoral Stem: A Prospective 2-Year Radiostereometric Analysis Study.Arthroplasty today · 2023Article
- Cementless total hip arthroplasty with anatomic-shaped implants. Does the minimal invasive anterolateral technique influence the stem position or subsidence in contrast to the standard lateral approach?Archives of orthopaedic and trauma surgery · 2022Article
- 5-Year Clinical and Radiographic Results of the Direct Anterior Approach for Total Hip Arthroplasty Using a Collared Cementless Femoral Short-Stem Prosthesis.Journal of clinical medicine · 2022Article
- Direct anterior approach or posterior approach in total hip arthroplasty: A direct comparative study protocol.Medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionEarly research shows several advantages of the direct anterior approach (DAA) in THA that claimed to be as effective but less invasive than the posterior approach. However, due to the difficult femoral exposure and possible complications related to femoral preparation, this approach may result in a higher rate of undersized stems when compared to other approaches. The present authors believe that the femoral implant design (collar or collarless stem, short or long stem) in a collared femoral stem may relate to lower rates of stem subsidence and limb length discrepancy (LLD) in mid-term to long-term follow-up when compared to collarless femoral stems. However, currently, there is no consensus as to which femoral implant design is the most suitable for DAA in THA.
methodsThis systematic review and meta-analysis aim to assess and compare postoperative complications (neurapraxia, wound infection, LFCN, hematoma, artery injury, cup malposition, embolism, fracture and implant loosening) and revision rates due to dislocation, periprosthetic fracture and implant migration after DAA using collared compared to collarless femoral stem and short femoral stem compared to long femoral stem in THA. These clinical outcomes consist of the postoperative complications and revision femoral stem due to neurapraxia, wound, LFCN and LLD. This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
resultsRelevant studies that reported postoperative complications and revision of either implant were identified from Medline and Scopus from inception to June 6, 2018. Thirty-four studies were included for the analysis of DAA in THA; 23 studies were retrospective cohorts, four studies were prospective cohorts, and seven studies were RCTs. Thirty-one studies and three studies were included for analysis of collarless and collared femoral stems. Twenty-six studies were long femoral stems and eight studies were short femoral stems. Overall, there were 6825 patients (6457 in the collarless group and 368 in the collared group, 4280 in long stem and 2545 in short stem). A total of 469 and 66 patients had complications and revisions in the collarless group, and no patient had complications and revisions in the collared stem group. The total complication and revision rate per patient were 5% (95%CI 3.3%, 7%) and 0.9% (95%CI 0.6%, 1.2%) in all patients. The complication rate and revision rate were 5.7% (95%CI 3.8%, 7.7%) and 0.9% (95%CI 0.6, 1.2) in the collarless group. There was no prevalence of complications and revisions in the collared stem group. The complication rate and revision rate were 10.2% (95%CI 9%, 11.4%), 0.7% (95%CI 0.3%, 1%) and 5.2% (95%CI 3.1, 7.2), 1.5% (95%CI 1%, 2%) in short and long femoral stems, respectively. Indirect meta-analysis shows that collared femoral stem provided a lower risk of complications of 0.02 (95%CI 0.001, 0.30) when compared to collarless femoral stem. Long femoral stems had a lower risk of having complications of 0.57 (95%CI 0.48, 0.68) when compared to short femoral stems. In terms of revision, there is no statistically significant difference in collared femoral stem compared to collarless femoral stem and long femoral stem compared to short femoral stem.
conclusionIn DAA THA, collared femoral stem and long femoral stem had decreased complication rates when compared to collarless femoral stem and short femoral stem by both direct and indirect meta-analysis methods. However, in terms of revision rates, there were no differences between all femoral stems (short versus long and collared versus collarless). Prospective randomized controlled studies are needed to confirm these findings as the current literature is still insufficient.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.