Biomechanical behavior of three types of fixation in the two-part proximal humerus fracture without medial cortical support.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 8 citations in OpenAlex.
- Comparison of three reconstruction techniques for medial column support loss in elderly patients with proximal humeral fractures.Frontiers in medicine · 2026Article
- Efficacy of PHILOS combined with n-HA/PA66 augmentation for treating three- or four-part proximal humeral fractures in elderly patients.Journal of orthopaedic surgery and research · 2025Article
- Comparative analysis of unicortical vs. subchondral locking screws in osteoporotic proximal humerus fractures.Heliyon · 2025Article
- Preventing varus collapse in proximal humerus fracture fixation: 90-90 dual plating versus endosteal fibular allograft strut.Archives of orthopaedic and trauma surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of this study was to evaluate the role of a non-locking plate applied to the anteromedial surface of the proximal humerus on loads at the implant-bone interface of non-locking and locking lateral plate fixation of proximal humeral fractures with a medial gap.
methodsTwenty synthetic humeri models were used. In fifteen, the proximal portion of the humerus was osteotomized to create a two-part surgical neck fracture, with a 10-mm medial gap and a 5-mm lateral gap; five models were controls. In the osteotomized humeri, five models were stabilized with a locking lateral plate (group L), five with a locking lateral plate and an anteromedial non-locking plate (group L+T), and five with a non-locking lateral plate and a non-locking anteromedial plate (group T+T). All humeri were tested under axial loading until catastrophic failure, which was characterized as complete closure of the medial gap. Stiffness was calculated using force vs. displacement curves. The data were analyzed via descriptive and inferential studies, at a 5% significance level.
resultsStatistically significant differences were seen among all the constructions. The combination of a lateral locking plate with an anteromedial non-locking plate (group L+T) was the stiffest construction, while the combination of a non-locking lateral plate with a non-locking anteromedial plate (group T+T) was the least stiff, even in comparison with a single locking lateral plate (p = 0.01). When the two groups which utilized a lateral locking plate (groups L+T and L) were compared, the group with additional anteromedial support demonstrated greater stiffness (p = 0.03), and stiffness values for the control group comprised of intact humeri models were even higher (p = 0.01).
conclusionCombining a lateral locking plate with a non-locking anteromedial plate provides a stiffer construction for fixation of unstable two-part proximal humerus fractures with a medial gap. Mechanical benefits of medial support with a second non-locking antero-medial plate seems to be related with better construct stability in terms of strength and fatigue, potentially reducing the risk of varus collapse of the humerus head and fracture healing disturbances.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.