Evidence map›Paper›PMID 31357580›Full record

ArticleMaterials (Basel, Switzerland)2019

The Electrochemical and Mechanical Behavior of Bulk and Porous Superelastic Ti‒Zr-Based Alloys for Biomedical Applications.

Yulia Zhukova, Anastasia Korobkova, Sergey Dubinskiy, Yury Pustov, Anton Konopatsky, Dmitry Podgorny, Mikhail Filonov, Sergey Prokoshkin, Vladimir Brailovski

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yulia ZhukovaCenter of Nanomaterials and Nanotechnologies, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia. zhukova@misis.ru.
Anastasia KorobkovaCenter of Nanomaterials and Nanotechnologies, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Sergey DubinskiyMetal Forming Department, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Yury PustovMetal Forming Department, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Anton KonopatskyCenter of Nanomaterials and Nanotechnologies, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Dmitry PodgornyMaterials Science of Semiconductors and Dielectrics Department, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Mikhail FilonovDepartment of Functional Nanosystems and High-Temperature Materials, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Sergey ProkoshkinMetal Forming Department, National University of Science and Technology "MISIS", 4 Leninskiy prospekt, Moscow 119049, Russia.
Vladimir BrailovskiShape Memory Alloys and Intelligent Systems Laboratory (LAMSI), École de Technologie Supérieure (ETS), 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.

Funding

Ministry of Education and Science of the Russian Federation K4-2014-018Ministry of Education and Science of the Russian Federation State Task No. 11.1495.2017/4.6Natural Sciences and Engineering Research Council of Canada Discovery GrantRussian Foundation for Basic Research research project № 18-08-01193 А
6 · The paper itself

Abstract

Titanium alloys are well recognized as appropriate materials for biomedical implants. These devices are designed to operate in quite aggressive human body media, so it is important to study the corrosion and electrochemical behavior of the novel materials alongside the underlying chemical and structural features. In the present study, the prospective Ti‒Zr-based superelastic alloys (Ti-18Zr-14Nb, Ti-18Zr-15Nb, Ti-18Zr-13Nb-1Ta, atom %) were analyzed in terms of their phase composition, functional mechanical properties, the composition and structure of surface oxide films, and the corresponding corrosion and electrochemical behavior in Hanks' simulated biological solution. The electrochemical parameters of the Ti-18Zr-14Nb material in bulk and foam states were also compared. The results show a significant difference in the functional performance of the studied materials, with different composition and structure states. In particular, the positive effect of the thermomechanical treatment regime, leading to the formation of a favorable microstructure on the corrosion resistance, has been revealed. In general, the Ti-18Zr-15Nb alloy exhibits the optimum combination of functional characteristics in Hanks' solution, while the Ti-18Zr-13Nb-1Ta alloy shows the highest resistance to the corrosion environment. The Ti-18Zr-14Nb-based foam material exhibits slightly lower passivation kinetics as compared to its bulk equivalent.

Indexed as

biocompatibilitycorrosion resistanceimplantsmartensitic transformationmicrostructureoxide filmshape memory materialssuperelastic materialsthermomechanical treatment

Identifiers

PMID31357580
PMCPMC6696258

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.