Evidence map›Paper›PMID 31347328›Full record

ArticleYonsei medical journal2019

Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor.

Go Eun Kim, So Yeon Kim, Seon Ju Kim, Soon Young Yun, Hwan Ho Jung, Yhen Seung Kang, Bon Nyeo Koo

Open access · goldAbstract read
In one paragraph

Article in Yonsei medical journal, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Refining STEMI Prognosis: Expanding the Role of Noninvasive Cardiac Monitoring Beyond the GRACE Score.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Go Eun KimDepartment of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-2323-9383
So Yeon KimDepartment of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-5352-157X
Seon Ju KimDepartment of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-1911-8143
Soon Young YunDepartment of Anesthesiology and Pain Medicine, Gachon University Gil Medical Center, Incheon, Korea.ORCID https://orcid.org/0000-0002-2881-7579
Hwan Ho JungDepartment of Anesthesiology and Pain Medicine, National Health Insurance Service Ilsan Hospital, Goyang, Korea.ORCID https://orcid.org/0000-0002-3819-2744
Yhen Seung KangDepartment of Anesthesiology and Pain Medicine, National Health Insurance Service Ilsan Hospital, Goyang, Korea.ORCID https://orcid.org/0000-0002-1622-7694
Bon Nyeo KooDepartment of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea. KOOBN@yuhs.ac.ORCID https://orcid.org/0000-0002-3189-1673
Yonsei University · KRNational Health Insurance Service Ilsan Hospital · KRGachon University Gil Medical Center · KR

Funding

National Research Foundation of Korea NRF-2017R1A2B4009478
6 · The paper itself

Abstract

purposeThe most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive CO monitoring technique. This study compared the accuracy and efficacy of ICG as a non-invasive cardiac function monitoring technique to those of thermodilution and arterial pressure contour. MATERIALS AND

methodsSixteen patients undergoing liver transplantation were included. Cardiac index (CI) was measured by thermodilution using PAC, arterial waveform analysis, and ICG simultaneously in each patient. Statistical analysis was performed using intraclass correlation coefficient (ICC) and Bland-Altman analysis to assess the degree of agreement.

resultsThe difference by thermodilution and ICG was 1.13 L/min/m², and the limits of agreement were -0.93 and 3.20 L/min/m². The difference by thermodilution and arterial pressure contour was 0.62 L/min/m², and the limits of agreement were -1.43 and 2.67 L/min/m². The difference by arterial pressure contour and ICG was 0.50 L/min/m², and the limits of agreement were -1.32 and 2.32 L/min/m². All three percentage errors exceeded the 30% limit of acceptance. Substantial agreement was observed between CI of thermodilution with PAC and ICG at preanhepatic and anhepatic phases, as well as between CI of thermodilution and arterial waveform analysis at preanhepatic phase. Others showed moderate agreement.

conclusionAlthough neither method was clinically equivalent to thermodilution, ICG showed more substantial correlation with thermodilution method than with arterial waveform analysis. As a non-invasive cardiac function monitor, ICG would likely require further studies in other settings.

Indexed as

Cardiography, ImpedanceHeart Function TestsMonitoring, PhysiologicCardiac OutputFemaleHumansLiver TransplantationMaleMiddle AgedCardiac outputimpedance cardiographyliver transplantationthermodilution

Identifiers

PMID31347328
PMCPMC6660442
OpenAlexW2962929753

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.