Evidence map›Paper›PMID 31346514›Full record

ArticleBioMed research international2019

Short to Midterm Follow-Up of Periprosthetic Bone Mineral Density after Total Hip Arthroplasty with the Ribbed Anatomic Stem.

Xiang-Dong Wu, Mian Tian, Yao He, Hong Chen, Yu Chen, Rahul Mishra, Wei Liu, Wei Huang

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Comparison of Bone Remodeling Between Collum Femoris-Preserving Stems and Ribbed Stems in 1-Stage Bilateral Total Hip Arthroplasty.Medical science monitor : international medical journal of experimental and clinical research · 2020
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Xiang-Dong WuDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.ORCID https://orcid.org/0000-0002-3920-4372
Mian TianDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.
Yao HeDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.ORCID https://orcid.org/0000-0002-5147-9037
Hong ChenDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.
Yu ChenDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.
Rahul MishraDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.
Wei LiuDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.ORCID https://orcid.org/0000-0002-5650-7332
Wei HuangDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.ORCID https://orcid.org/0000-0002-8894-0982
The Affiliated Yongchuan Hospital of Chongqing Medical University · CNSiddhartha University · NP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFemoral bone remodeling around hip prosthesis after total hip arthroplasty (THA) is definite but unpredictable in time and place. This study aimed to investigate the implant-specific remodeling and periprosthetic bone mineral density (BMD) changes after implantation of the Ribbed anatomic cementless femoral stem.

methodsAfter power analysis, 41 patients who had undergone primary unilateral THA with the Ribbed anatomic cementless stem were included. BMD of the seven Gruen zones was measured by dual-energy X-ray absorptiometry, and the contact, fitness, and fixation of the femoral stem and proximal femur were analyzed by X-ray. Additional clinical outcome parameters were also recorded.

resultsCompared with the contralateral unoperated side, significant reductions of BMD were detected in the distal zone (Gruen zone 4: 1.665±0.198

conclusionsFor the Ribbed femoral stem, the periprosthetic BMD was well maintained in the proximal femur, while periprosthetic BMD was significantly reduced in the distal and middle distal zones of the femur. Further clinical investigations are required to examine the efficacy of the Ribbed stem, particularly with regard to long-term survival. This trial is registered with ChiCTR1800017750.

Indexed as

Bone RemodelingAbsorptiometry, PhotonAdultAgedArthroplasty, Replacement, HipBone DensityFemaleFemurFollow-Up StudiesHip ProsthesisHumansMaleMiddle AgedProsthesis DesignRadiography

Identifiers

PMID31346514
PMCPMC6620856
OpenAlexW2954995357

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.