ArticleIEEE robotics and automation letters2019
Sensorless Estimation of the Planar Distal Shape of a Tip-Actuated Endoscope.
Article in IEEE robotics and automation letters, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Traditional endoscopes consist of a flexible body and a steerable tip with therapeutic capability. Although prior endoscopes have relied on operator pushing for actuation, recent robotic concepts have relied on the application of a tip force for guidance. In such case, the body of the endoscope can be passive and compliant; however, the body can have significant effect on mechanics of motion and may require modeling. As the endoscope body's shape is often unknown, we have developed an estimation method to recover the approximate distal shape, local to the endoscope's tip, where the tip position and orientation are the only sensed parameters in the system. We leverage a planar dynamic model and extended Kalman filter to obtain a constant-curvature shape estimate of a magnetically guided endoscope. We validated this estimator in both dynamic simulations and on a physical platform. We then used this estimate in a feed-forward control scheme and demonstrated improved trajectory following. This methodology can enable the use of inverse-dynamic control for the tip-based actuation of an endoscope, without the need for shape sensing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.