Evidence map›Paper›PMID 31339208›Full record

ArticleAnnals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc2020

Assessment of signal quality measured with a smart 12-lead ECG acquisition T-shirt.

David Fouassier, Xavier Roy, Anne Blanchard, Jean-Sébastien Hulot

Abstract read
In one paragraph

Article in Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Smart devices to measure and monitor QT intervals.Frontiers in cardiovascular medicine · 2023
    Review
  10. Article
  11. The Recent Advances of Mobile Healthcare in Cardiology Practice.Acta informatica medica : AIM : journal of the Society for Medical Informatics of Bosnia & Herzegovina : casopis Drustva za medicinsku informatiku BiH · 2022
    Review
  12. How to use digital devices to detect and manage arrhythmias: an EHRA practical guide.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2022
    Article
  13. Review
  14. Article
  15. Review
  16. Article
  17. [Research progress on wearable physiological parameter monitoring and its clinical applications].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021
    Review
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

David FouassierAssistance Publique Hôpitaux de Paris, Centre d'Investigations Cliniques CIC1418, Hôpital Européen Georges Pompidou, Paris, France.
Xavier RoyAssistance Publique Hôpitaux de Paris, Centre d'Investigations Cliniques CIC1418, Hôpital Européen Georges Pompidou, Paris, France.
Anne BlanchardAssistance Publique Hôpitaux de Paris, Centre d'Investigations Cliniques CIC1418, Hôpital Européen Georges Pompidou, Paris, France.
Jean-Sébastien HulotAssistance Publique Hôpitaux de Paris, Centre d'Investigations Cliniques CIC1418, Hôpital Européen Georges Pompidou, Paris, France.ORCID 0000-0001-5463-6117

Funding

Bioserenity, Paris, France
6 · The paper itself

Abstract

backgroundAmbulatory ECG monitoring is typically achieved using portable devices with limited number of surface leads, autonomy, and length of recording. Smart garments with multiple conductive textile electrodes provide great promise to perform continuous and comfortable ECG monitoring.

methodsWe evaluated the ECG signal quality measured on healthy subjects with a smart 12-lead ECG acquisition T-shirt or a 12-lead Holter recording. ECG signals were recorded during 3 min with both techniques in three resting positions (supine, seated, standing) and while walking. Three readers independently assessed ECG patterns and evaluated the denoising of the isoelectric line, the distinction of p waves, R peaks and RR intervals, and the possible appreciation of cardiac rhythm in at least 3 leads.

resultsThirty healthy subjects (70% males, 29.5 ± 7.8 years) were enrolled in the study. For all three resting conditions, cardiac rhythm was appreciated in 100% of recordings with distinction of p waves, R peaks, and isoelectric line in >97% of recordings. Appreciation of cardiac rhythm was lower in the walking conditions with both techniques (53.3% vs. 46.7%, Holter vs. smart T-shirt, p = .60) mainly due to difficulties to distinguish p waves. These results were consistent across both genders. All ECG parameters (heart rate, PR, QRS and QTC intervals) were comparable between both techniques. No skin irritation was seen with the textile electrodes.

conclusionsA smart T-shirt with 13 textiles electrodes allows short-duration 12-lead ECG acquisition with quality levels comparable to Holter recordings. The novel device should now be evaluated for long-term non-invasive ECG monitoring.

Indexed as

ClothingAdultElectrocardiography, AmbulatoryFemaleHumansMaleProspective StudiesReference ValuesReproducibility of ResultsSignal Processing, Computer-AssistedcardiologyECGe-textilegarmentHoltertelemedicinewearable

Identifiers

PMID31339208
PMCPMC7050501

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.