Evidence map›Paper›PMID 31328368›Full record

ArticleJournal of applied clinical medical physics2019

Frame-based radiosurgery of multiple metastases using single-isocenter volumetric modulated arc therapy technique.

Kang-Hyun Ahn, Kamil M Yenice, Matthew Koshy, Konstantin V Slavin, Bulent Aydogan

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Verification of stereotactic radiosurgery plans for multiple brain metastases using a virtual phantom-based procedure.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2022
    Article
  3. Radiosurgery for multiple brain metastases using volumetric modulated arc therapy: a single institutional series.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2022
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Kang-Hyun AhnDepartment of Radiation Oncology, University of Illinois, Chicago, IL, USA.
Kamil M YeniceDepartment of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, USA.
Matthew KoshyDepartment of Radiation Oncology, University of Illinois, Chicago, IL, USA.
Konstantin V SlavinDepartment of Neurosurgery, University of Illinois, Chicago, IL, USA.
Bulent AydoganDepartment of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, USA.
Illinois College · USUniversity of Chicago · USUniversity of Illinois Chicago · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Single-isocenter volumetric modulated arc therapy (VMAT) technique can provide stereotactic radiosurgery (SRS) treatment with improved delivery efficiency for treating multiple metastases. Nevertheless, planning is time consuming and verification of frame-based SRS setup, especially at noncoplanar angles, can be challenging. We report on a single-isocenter VMAT technique with a special focus on improving treatment workflow and delivery verification to exploit the minimized patient motion of the frame-based SRS. We developed protocols for preplanning and verification for VMAT and evaluated them for ten patient cases. Preplans based on MRI were used to generate comparable treatment plans using CT taken on the day of treatment after frame placement. Target positioning accuracy was evaluated by stereoscopic in-room kV imaging. Dosimetric accuracy of the noncoplanar plan delivery was validated using measurement-guided 3D dose reconstruction as well as film-based end-to-end test with a Rando phantom. Average absolute differences of homogeneity indices, conformity indices, and V12Gy between MR preplans and CT-based plans were within 5%. In-room imaging positioning accuracy of 0.4 mm was verified to be independent of the distance to the isocenter. For treatment verification, average local and global passing rates of the 3D gamma (1 mm, 3%) were 86% and 99%, respectively. D99 values were matched within 5% for individual target structures (>0.5 cc). Additional film analysis confirmed dosimetric accuracy for small targets that had large verification errors in the 3D dose reconstruction. Our results suggest that the advantages of frame-based SRS and noncoplanar single-isocenter VMAT technique can be combined for efficient and accurate treatment of patients with multiple metastases.

Indexed as

AlgorithmsBrain NeoplasmsHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingOrgans at RiskPrognosisRadiosurgeryRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computedframe-based SRSmultiple metastasessingle-isocenter volumetric modulated arc therapyVMAT SRS

Identifiers

PMID31328368
PMCPMC6698758
OpenAlexW2963793983

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.