Evidence map›Paper›PMID 31328028›Full record

ArticlePeerJ2019

A new comprehensive eye-tracking test battery concurrently evaluating the Pupil Labs glasses and the EyeLink 1000.

Benedikt V Ehinger, Katharina Groß, Inga Ibs, Peter König

Open access · goldAbstract read
In one paragraph

Article in PeerJ, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 61 papers.

0numbers the graph read from it
0cells of the map it votes in
61citing papers in PubMed
10.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

61 citing papers in PubMed, 131 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article

1 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Benedikt V Ehinger *Institute of Cognitive Science, Osnabrück University, Osnabrück, Germany.ORCID 0000-0002-6276-3332
Katharina Groß *Institute of Cognitive Science, Osnabrück University, Osnabrück, Germany.ORCID 0000-0002-3505-9999
Inga IbsInstitute of Cognitive Science, Osnabrück University, Osnabrück, Germany.
Peter KönigInstitute of Cognitive Science, Osnabrück University, Osnabrück, Germany.ORCID 0000-0003-3654-5267
Osnabrück University · DERadboud University Nijmegen · NLUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Eye-tracking experiments rely heavily on good data quality of eye-trackers. Unfortunately, it is often the case that only the spatial accuracy and precision values are available from the manufacturers. These two values alone are not sufficient to serve as a benchmark for an eye-tracker: Eye-tracking quality deteriorates during an experimental session due to head movements, changing illumination or calibration decay. Additionally, different experimental paradigms require the analysis of different types of eye movements; for instance, smooth pursuit movements, blinks or microsaccades, which themselves cannot readily be evaluated by using spatial accuracy or precision alone. To obtain a more comprehensive description of properties, we developed an extensive eye-tracking test battery. In 10 different tasks, we evaluated eye-tracking related measures such as: the decay of accuracy, fixation durations, pupil dilation, smooth pursuit movement, microsaccade classification, blink classification, or the influence of head motion. For some measures, true theoretical values exist. For others, a relative comparison to a reference eye-tracker is needed. Therefore, we collected our gaze data simultaneously from a remote EyeLink 1000 eye-tracker as the reference and compared it with the mobile Pupil Labs glasses. As expected, the average spatial accuracy of 0.57° for the EyeLink 1000 eye-tracker was better than the 0.82° for the Pupil Labs glasses (

Indexed as

Accuracy and precisionBlinksCalibration decayEyeLink 1000Eye-tracker benchmarkHead movementsMicrosaccadesPupil dilationPupil Labs glassesSmooth pursuit

Identifiers

PMID31328028
PMCPMC6625505
OpenAlexW2957625227

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked