Evidence map›Paper›PMID 31324259›Full record

ArticleVirology journal2019

Comparison of the detection performance of two different one-step-combined test strips with fluorescent microspheres or colored microspheres as tracers for influenza A and B viruses.

Qingjun Pan, Weiquan Wu, Shuzhen Liao, Sijie Wang, Chunfei Zhao, Chen Li, Ping Wu

Open access · goldAbstract readComparative Study
In one paragraph

Article in Virology journal, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Qingjun PanInstitute of Nephrology, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.ORCID 0000-0002-8060-9099
Weiquan WuClinical Research Center, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.
Shuzhen LiaoInstitute of Nephrology, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.
Sijie WangClinical Research Center, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.
Chunfei ZhaoInstitute of Nephrology, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.
Chen LiDepartment of Clinical Laboratory, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China. 287032627@qq.com.
Ping WuClinical Research Center, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China. wping62@126.com.
Guangdong Medical College · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInfluenza A and B viruses mainly cause respiratory infectious disease. Till now, few tests are able to simultaneously detect both, especially in primary medical establishments.

methodsThis study was designed to compare the performance of two different one-step-combined test strips for the detection of influenza A and B: one strip with fluorescent microspheres for tracers (FMT); and the other strip with colored microspheres for tracers (CMT). To test the strips, cultures of influenza A, B, and other pathogenic viruses were used, in addition to 1085 clinical specimens from symptomatic patients with respiratory infections. Real-time RT-PCR was also considered as a reference method used to detect the different results of FMT and CTM.

resultsDetection thresholds for influenza A and B cultures using serial dilutions revealed that the sensitivity of FMT was higher than that of CMT (both P < 0.05). With the culture mixtures of Coxsackie virus (A16), enteric cytopathic human orphan virus (ECHO type30), enterovirus (EV71), rotavirus (LLR strain), and enteric adenovirus (AdV 41), specificity assessment demonstrated that there was no cross reaction during the usage of the two test strips as shown by the results which were negative. In the detection of influenza A in 1085 clinical specimens, the total coincidence rate was 96.7%, the positive coincidence rate was 97.1%, and the negative coincidence rate was 96.7%. In the case of influenza B detection, the total coincidence rate was 99.1%, the positive coincidence rate was 92.6%, and the negative coincidence rate was 98.5%. In addition, with influenza A or B real-time RT-PCR detection method, the results showed that, for influenza A, 26 of the 33 specimens that negative with CMT but positive with FMT, showed positive results, and none of the 3 specimens that positive with CMT but negative with FMT showed a positive result; For influenza B, 12 of the 15 specimens that negative with CMT but positive with FMT, showed positive results, and none of the 5 specimens that positive with CMT but negative with FMT showed a positive result.

conclusionsFMT performed better than CMT in the combined detection of influenza A and B viruses.

Indexed as

MicrospheresColorFluorescenceHumansInfluenza A virusInfluenza B virusInfluenza, HumanReagent StripsRespiratory Tract InfectionsReagent StripsColored microspheresFluorescent microspheresInfluenza AInfluenza BOne step combined test

Identifiers

PMID31324259
PMCPMC6642511
OpenAlexW2962860086

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.