Evidence map›Paper›PMID 31317295›Full record

ArticleBiomechanics and modeling in mechanobiology2020

Finite element evaluation of artery damage in deployment of polymeric stent with pre- and post-dilation.

R He, L G Zhao, V V Silberschmidt, Y Liu, F Vogt

Open access · hybridAbstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. A Review on Damage and Rupture Modelling for Soft Tissues.Bioengineering (Basel, Switzerland) · 2022
    Review
  7. Article
  8. Article
  9. Article
  10. [Review of studies on the biomechanical modelling of the coupling effect between stent degradation and blood vessel remodeling].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

R HeWolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK.
L G ZhaoWolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK. L.Zhao@Lboro.ac.uk.ORCID http://orcid.org/0000-0003-1265-0468
V V SilberschmidtWolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK.
Y LiuWolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK.
F VogtMedical Clinic I, University Hospital Aachen, Pauwelsstrasse 30, 52074, Aachen, Germany.
Loughborough University · GBUniversitätsklinikum Aachen · DE

Funding

British Heart Foundation FS/15/21/31424Engineering and Physical Sciences Research Council EP/R001650/1The Royal Society of UK IE160066
6 · The paper itself

Abstract

Using finite element method, this paper evaluates damage in an arterial wall and plaque caused by percutaneous coronary intervention. Hyperelastic damage models, calibrated with experimental results, are used to describe stress-stretch responses of arterial layers and plaque; these models are capable to simulate softening behaviour of the tissue due to damage. Abaqus CAE is employed to create the finite element models for the artery wall (with media and adventitia layers), a symmetric uniform plaque, a bioresorbable polymeric stent and a tri-folded expansion balloon. The effect of percutaneous coronary intervention on vessel damage is investigated by simulating the processes of vessel pre-dilation, stent deployment and post-stenting dilation. Energy dissipation density is used to assess the extent of damage in the tissue. Softening of the plaque and the artery, due to the pre-dilation-induced damage, can facilitate the subsequent stent deployment process. The plaque and the artery experienced heterogeneous damage behaviour after the stent deployment, caused by non-uniform deformation. The post-stenting dilation was effective to achieve a full expansion of the stent, but caused additional damage to the artery. The continuous and discontinuous damage models yielded similar results in the percutaneous coronary intervention simulations, while the incorporation of plaque rupture affected the simulated outcomes of stent deployment. The computational evaluation of the artery damage can be potentially used to assess the risk of in-stent restenosis after percutaneous coronary intervention.

Indexed as

Finite Element AnalysisStentsArteriesComputer SimulationDilatationHumansModels, CardiovascularPlaque, AtheroscleroticPolymersStress, MechanicalPolymersArtery damageHyperelastic damage modelPlaque rupturePre/post-dilationStent deployment

Identifiers

PMID31317295
PMCPMC7005093
OpenAlexW2957664855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.