ArticleAnnals of translational medicine2019
Detecting insertion, substitution, and deletion errors in radiology reports using neural sequence-to-sequence models.
Article in Annals of translational medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.
- A systematic review of natural language processing applied to radiology reports.BMC medical informatics and decision making · 2021Pooled it
- Improving Radiology Report Error Detection Using a Multipass Large Language Model: Framework Development and Validation.JMIR medical informatics · 2026Article
- Neuro Data Hub: A New Approach for Streamlining Medical Clinical Research.Neurosurgery practice · 2025Article
- Article
- Generative Large Language Models for Detection of Speech Recognition Errors in Radiology Reports.Radiology. Artificial intelligence · 2024Article
- Using automated methods to detect safety problems with health information technology: a scoping review.Journal of the American Medical Informatics Association : JAMIA · 2023Article
- Using BERT Models to Label Radiology Reports.Radiology. Artificial intelligence · 2022Article
- Application of a Domain-specific BERT for Detection of Speech Recognition Errors in Radiology Reports.Radiology. Artificial intelligence · 2022Article
- Automated Misspelling Detection and Correction in Persian Clinical Text.Journal of digital imaging · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundErrors in grammar, spelling, and usage in radiology reports are common. To automatically detect inappropriate insertions, deletions, and substitutions of words in radiology reports, we proposed using a neural sequence-to-sequence (seq2seq) model.
methodsHead CT and chest radiograph reports from Mount Sinai Hospital (MSH) (n=61,722 and 818,978, respectively), Mount Sinai Queens (MSQ) (n=30,145 and 194,309, respectively) and MIMIC-III (n=32,259 and 54,685) were converted into sentences. Insertions, substitutions, and deletions of words were randomly introduced. Seq2seq models were trained using corrupted sentences as input to predict original uncorrupted sentences. Three models were trained using head CTs from MSH, chest radiographs from MSH, and head CTs from all three collections. Model performance was assessed across different sites and modalities. A sample of original, uncorrupted sentences were manually reviewed for any error in syntax, usage, or spelling to estimate real-world proofreading performance of the algorithm.
resultsSeq2seq detected 90.3% and 88.2% of corrupted sentences with 97.7% and 98.8% specificity in same-site, same-modality test sets for head CTs and chest radiographs, respectively. Manual review of original, uncorrupted same-site same-modality head CT sentences demonstrated seq2seq positive predictive value (PPV) 0.393 (157/400; 95% CI, 0.346-0.441) and negative predictive value (NPV) 0.986 (789/800; 95% CI, 0.976-0.992) for detecting sentences containing real-world errors, with estimated sensitivity of 0.389 (95% CI, 0.267-0.542) and specificity 0.986 (95% CI, 0.985-0.987) over n=86,211 uncorrupted training examples.
conclusionsSeq2seq models can be highly effective at detecting erroneous insertions, deletions, and substitutions of words in radiology reports. To achieve high performance, these models require site- and modality-specific training examples. Incorporating additional targeted training data could further improve performance in detecting real-world errors in reports.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials