ArticleOrthopedic reviews2019
Single versus separate implant fixation for concomitant ipsilateral femoral neck and shaft fractures: A systematic review.
Article in Orthopedic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.
- Comparison of reconstruction nails versus dual implants in the treatment of ipsilateral femoral neck and shaft fractures in adults: a meta-analysis and systematic review.BMC musculoskeletal disorders · 2023Pooled it
- A 44-Year-Old Male Manual Laborer With Nonunion of a Femoral Neck Fracture Treated With Ultrasound-Guided Percutaneous Injections of Platelet-Rich Plasma: A Case Report.The American journal of case reports · 2026Article
- Finite element analysis of four different fixation methods for the treatment of ipsilateral femoral neck and shaft fractures.BMC musculoskeletal disorders · 2026Article
- Finite element analysis of long proximal femoral bionic nail (PFBN) fixation for femoral shaft fractures combined with ipsilateral femoral neck fractures.Frontiers in bioengineering and biotechnology · 2026Article
- Percutaneous joystick reduction with reductor-T tape pin and fixation with a reconstruction nail for the treatment of ipsilateral femoral neck and shaft fractures.Joint diseases and related surgery · 2025Article
- Quantitative biomechanical analysis of fracture patterns in ipsilateral femoral neck and shaft fractures: an in-silico study.Frontiers in bioengineering and biotechnology · 2025Article
- Surgical fixation of ipsilateral femoral neck and shaft fractures: a matter of debate?EFORT open reviews · 2023Review
- Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021Article
- Article
- Femoral Neck Nonunion Associated With Delayed Union of Ipsilateral Femoral Shaft Fracture.Cureus · 2021Article
- Article
- The rendezvous technique for the treatment of ipsilateral femoral neck and shaft fractures: A case series.Trauma case reports · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Concomitant ipsilateral femoral neck and shaft fractures are uncommon, occurring in 1-9% of femoral shaft fractures. While this injury typically occurs in young patients following high-energy trauma, little consensus has been established regarding the optimal fixation approach. A multitude of treatment strategies exist, with limited evidence as to which is more favorable. The aim of this study was to appraise current evidence, comparing management with either one single or separate devices for both fractures. A systematic review was undertaken in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies published between 1992 and 2018 comparing the rate of postoperative nonunion, malunion, delayed union, avascular necrosis, infection or reoperation between at least one method of single device fixation and one method of separate device fixation were included. Six non-randomized cohort studies assessing 173 patients were suitable for inclusion, each comparing single device cephalomedullary nail fixation of both fractures with a combination of devices. All patients presented following high-energy trauma, at a median age of 32 years. While low complication rate and favorable outcomes were found across both groups, no significant difference could be inferred between either treatment strategy. This injury continues to occur in the traditionally described patient group, and results in acceptable postoperative outcomes. A paucity of randomized studies limits the ability to recommend a single or separate device treatment approach, and as such prospective, randomized trials with adequately powered sample sizes are required to definitively compare surgical management strategies in this rare but complex injury.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.