ArticleJournal of medical ultrasound
Ultrasonic Assessment of Optic Nerve Sheath to Detect Increased Intracranial Pressure.
Article in Journal of medical ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- The potential of point-of-care diagnostics to optimise prehospital trauma triage: a systematic review of literature.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023Pooled it
- Estimate the severity of acute ischemic stroke by optic nerve sheath ultrasound.The ultrasound journal · 2025Article
- The effects of prone position on optic nerve sheath diameter and intraocular pressure in elective lumbar disc surgery.BMC anesthesiology · 2025Observational
- Clinical implications of real-time optic nerve sheath diameter assessment via critical care ultrasound in intracranial hypertension.Frontiers in neurology · 2025Article
- Measuring optic nerve sheath diameter in children: a simple ultrasound protocol for ICP assessment.Frontiers in pediatrics · 2025Article
- A Narrative Review of Point of Care Ultrasound Assessment of the Optic Nerve in Emergency Medicine.Life (Basel, Switzerland) · 2023Review
- A Review of the Methods of Non-Invasive Assessment of Intracranial Pressure through Ocular Measurement.Bioengineering (Basel, Switzerland) · 2022Review
- Value of Optic Nerve Sheath Diameter in Diagnosis and Follow Up of Patients with Disturbed Conscious Level.Eye and brain · 2022Article
- Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis.The ultrasound journal · 2021Article
- Brain-Relaxing Effect of Different Diuretic Regimens in Supratentorial Tumor Surgery: A Comparative Study Guided by Optic Nerve Sheath Diameter.Anesthesia, essays and researchesArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIncreased intracranial pressure (ICP) is one of the prevalent symptoms of trauma, especially traumatic headache, which requires quick action for the diagnosis and treatment. The optic nerve sheath diameter (ONSD) is a newly proposed technique for the detection of an increase in ICP. The aim of this study was to assess the efficacy of this new diagnostic method in patients with increased ICP induced by trauma.
methodsThis prospective study was conducted between December 2016 and February 2017. The patients with traumatic headache and who had been diagnosed with increased ICP using clinical signs and computed tomography scan were compared to the voluntary healthy group. In each patient, measurements were performed employing ultrasound three times on each eye in an axial region, and the mean of these sizes was obtained as the ONSD.
resultsA total of 112 participants were examined. The mean ONSD measurement of the patients and the voluntary healthy group was 6.01 ± 0.76 and 3.41 ± 0.56 mm in the right eye, 6.11 ± 0.75 and 3.39 ± 0.54 mm in the left eye, and 6.06 ± 0.75 and 4.02 ± 1.07 mm in both sides, respectively. The ONSD in the right and left sides had high and significant correlation in the patients (
conclusionsUltrasound performed on the diaphragm of the optic nerve with acceptable sensitivity can detect patients with an increase in ICP and can be efficacious in expediting the action needed to reduce ICP. Due to the sensitivity and specificity of the ultrasound and high accuracy of the diameter of optic nerve sheath in detecting increase in ICP, as well as considering the fact that ultrasound is a noninvasive and available technique; it can be performed at the patient's bedside.
Indexed as