ArticleMedical physics2019
A second-generation virtual-pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole-body PET/CT scanner.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 17 citations in OpenAlex.
- Development of a Prototype AWSM-PET Device for Augmented Whole-Body PET Imaging and Initial Human Study.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026Article
- Performance evaluation of the ACTIVE 7 MAX benchtop preclinical PET scanner in accordance with the NEMA NU 4-2008 standard.EJNMMI physics · 2025Article
- A data-driven approach for spatial alignment of PET add-on detectors with sub-millimeter accuracy.Physics in medicine and biology · 2025Article
- High-resolution Imaging Using Virtual-Pinhole PET Concept.PET clinics · 2024Review
- System resolution versus image uncertainty for positron emission tomography scanners.Journal of medical imaging (Bellingham, Wash.) · 2022Article
- Development and Characterization of Modular Readout Design for Two-Panel Head-and-Neck Dedicated PET System Based on CZT Detectors.IEEE transactions on radiation and plasma medical sciences · 2022Article
- Self-Collimating SPECT With Multi-Layer Interspaced Mosaic Detectors.IEEE transactions on medical imaging · 2021Article
- Multiplexing Readout for Time-of-Flight (TOF) PET Detectors Using Striplines.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Augmented Whole-Body Scanning via Magnifying PET.IEEE transactions on medical imaging · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
Abstract
purposeWe have developed a second-generation virtual-pinhole (VP) positron emission tomography (PET) device that can position a flat-panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region-of-interest using a whole-body PET/computed tomography (CT) scanner.
methodsWe constructed a flat-panel VP-PET device using 32 high-resolution detectors, each containing a 4
resultsThe repeatability in positioning the flat-panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP-PET insert device with the flat-panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual-panel VP-PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP-PET device that has a single flat-panel detector. The improvement is greater if the VP-PET device employs a dual-panel design.
conclusionsWe have developed a prototype flat-panel VP-PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions-of-interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP-PET device. This technology may become a cost-effective solution for organ-specific imaging tasks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials