ArticleMolecular & cellular proteomics : MCP2019
Bayesian Confidence Intervals for Multiplexed Proteomics Integrate Ion-statistics with Peptide Quantification Concordance.
Article in Molecular & cellular proteomics : MCP, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Expanding Targeted Instrumentation for Discovery Applications: Complement Reporter Ion Quantification with a Quadrupole-Ion Trap Instrument.Journal of proteome research · 2025Article
- Synergistic Arg-C Ultra and Lys-C Digestion for Quantitative Proteomics.bioRxiv : the preprint server for biology · 2025Article
- Decoding protein phosphorylation during oocyte meiotic divisions using phosphoproteomics.eLife · 2025Article
- The evolution of tenascins.BMC ecology and evolution · 2024Article
- Increasing the analytic power for multi-batch proteome profiling with isobaric mass tags.Nature methods · 2024Article
- A data analysis framework for combining multiple batches increases the power of isobaric proteomics experiments.Nature methods · 2024Article
- The sulfotransferase XB5850668.L is required to apportion embryonic ectodermal domains.Developmental dynamics : an official publication of the American Association of Anatomists · 2023Article
- The trouble with triples: Examining the impact of measurement error in mediation analysis.Genetics · 2023Article
- The Intriguing Landscape of Single-Cell Protein Analysis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022Review
- Challenges and Opportunities for Bayesian Statistics in Proteomics.Journal of proteome research · 2022Review
- Quantitative Accuracy and Precision in Multiplexed Single-Cell Proteomics.Analytical chemistry · 2022Review
- TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level.Journal of proteome research · 2021Article
- Triqler for MaxQuant: Enhancing Results from MaxQuant by Bayesian Error Propagation and Integration.Journal of proteome research · 2021Article
- Defining the carrier proteome limit for single-cell proteomics.Nature methods · 2021Article
- The gain-of-function alleleProceedings of the National Academy of Sciences of the United States of America · 2020Article
- A Bayesian Null Interval Hypothesis Test Controls False Discovery Rates and Improves Sensitivity in Label-Free Quantitative Proteomics.Journal of proteome research · 2020Article
- Article
- Article
- The Synthetic Phenotype of ΔmBio · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Multiplexed proteomics has emerged as a powerful tool to measure relative protein expression levels across multiple conditions. The relative protein abundances are inferred by comparing the signals generated by isobaric tags, which encode the samples' origins. Intuitively, the trust associated with a protein measurement depends on the similarity of ratios from the protein's peptides and the signal-strength of these measurements. However, typically the average peptide ratio is reported as the estimate of relative protein abundance, which is only the most likely ratio with a very naive model. Moreover, there is no sense on the confidence in these measurements. Here, we present a mathematically rigorous approach that integrates peptide signal strengths and peptide-measurement agreement into an estimation of the true protein ratio and the associated confidence (BACIQ). The main advantages of BACIQ are: (1) It removes the need to threshold reported peptide signal based on an arbitrary cut-off, thereby reporting more measurements from a given experiment; (2) Confidence can be assigned without replicates; (3) For repeated experiments BACIQ provides confidence intervals for the union, not the intersection, of quantified proteins; (4) For repeated experiments, BACIQ confidence intervals are more predictive than confidence intervals based on protein measurement agreement. To demonstrate the power of BACIQ we reanalyzed previously published data on subcellular protein movement on treatment with an Exportin-1 inhibiting drug. We detect ∼2× more highly significant movers, down to subcellular localization changes of ∼1%. Thus, our method drastically increases the value obtainable from quantitative proteomics experiments, helping researchers to interpret their data and prioritize resources. To make our approach easily accessible we distribute it via a Python/Stan package.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.