Evidence map›Paper›PMID 31300242›Full record

ArticleJournal of optometry

Agreement between Pentacam and handheld Auto-Refractor/Keratometer for keratometry measurement.

Hassan Hashemi, Samira Heydarian, Abbas Ali Yekta, Mohamadreza Aghamirsalim, Mahin Ahmadi-Pishkuhi, Mehrnaz Valadkhan, Hadi Ostadimoghaddam, Ahmad Ahmadzadeh Amiri, Mehdi Khabazkhoob

Abstract readComparative Study
In one paragraph

Article in Journal of optometry. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Agreement analysis.Journal of optometry
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Hassan HashemiNoor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran.
Samira HeydarianDepartment of Rehabilitation Science, School of Allied Medical Sciences, Mazandaran University of Medical Sciences, Sari, Iran.
Abbas Ali YektaDepartment of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.
Mohamadreza AghamirsalimEye Research Center, Tehran University of Medical Sciences, Tehran, Iran.
Mahin Ahmadi-PishkuhiNoor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran.
Mehrnaz ValadkhanNoor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran.
Hadi OstadimoghaddamRefractive Errors Research Center, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.
Ahmad Ahmadzadeh AmiriDepartment of Ophthalmology, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.
Mehdi KhabazkhoobDepartment of Medical Surgical Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran. Electronic address: Khabazkhoob@yahoo.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study was conducted to evaluate the level of agreement in keratometry measurements between a rotating Scheimpflug imaging-based system (Pentacam) and a handheld auto-refractokeratometer (handheld NIDEK ARK-30).

methodThis analytical cross-sectional study was conducted in the right eyes of 579 subjects. Keratometry measurements were conducted with the Pentacam and the handheld NIDEK ARK-30 systems. The SPSS Software version 22 and MedCalc V3 were applied to estimate descriptive statistics using paired t-test, Pearson correlation coefficient, 95% limits of agreement (LoA), and Bland-Altman plot.

resultsIn the total sample, the inter-device difference in the mean flat and steep keratometry values was -0.266 diopter (D) (P-value<0.001) and 0.052D (P-value=0.093), respectively. There was a significant difference in mean flat keratometry between the two devices in all groups of refractive errors (paired difference <0.5D and P-value<0.001). The difference in mean steep keratometry was significant only in myopic subjects (P-value=0.046). The 95% LoA between the two devices measurements was 2.51D, 3.98D, and 6.37D for flat keratometry and 2.6D, 3.2D, and 3.9D for steep keratometry in emmetropic, myopic, and hyperopic subjects, respectively.

conclusionOur study showed relatively wide limits of agreement between handheld NIDEK ARK-30 and Pentacam; therefore, these devices cannot be used interchangeably for measuring corneal curvature.

Indexed as

AdolescentAdultAgedAged, 80 and overBiometryChildCorneaCross-Sectional StudiesDiagnostic Techniques, OphthalmologicalEmmetropiaFemaleHumansHyperopiaIranMaleMiddle AgedAuto-refractoqueratómetro portátilHandheld auto-refractokeratometerKeratometeryPentacamQueratómetro

Identifiers

PMID31300242
PMCPMC6978591

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked