Evidence map›Paper›PMID 31297650›Full record

ArticleInternational journal of computer assisted radiology and surgery2019

Designing and validating a PVA liver phantom with respiratory motion for needle-based interventions.

Tonke L de Jong, Adriaan Moelker, Jenny Dankelman, John J van den Dobbelsteen

Open access · hybridAbstract readValidation Study
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Engineering functional and anthropomorphic models for surgical training in interventional radiology: A state-of-the-art review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Tonke L de JongBioMechanical Engineering Department, Delft University of Technology, Delft, The Netherlands. t.l.dejong@tudelft.nl.ORCID http://orcid.org/0000-0003-0137-2431
Adriaan MoelkerRadiology and Nuclear Medicine Department, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.
Jenny DankelmanBioMechanical Engineering Department, Delft University of Technology, Delft, The Netherlands.
John J van den DobbelsteenBioMechanical Engineering Department, Delft University of Technology, Delft, The Netherlands.
Delft University of Technology · NLErasmus MC · NL

Funding

Stichting voor de Technische Wetenschappen 12709
6 · The paper itself

Abstract

purposeThe purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles.

methodsImage segmentations of CT scans of four patients during inspiration and expiration were used to measure liver and rib displacement. An anthropomorphic liver mold based on a CT scan was 3D printed and filled with 5% w/w PVA-to-water, undergoing two freeze-thaw cycles, in addition to a 3D-printed compliant rib cage. They were both held in place by a PVA abdominal phantom. A sinusoidal motion vector, based on the measured liver displacement, was applied to the liver phantom by means of a motion stage. Liver, rib cage and needle deflection were tracked by placing electromagnetic sensors on the phantom. Liver and rib cage phantom motion was validated by comparison with the CT images of the patients, whereas needle deflection was compared with the literature.

resultsCT analysis showed that from the state of expiration to inspiration, the livers moved predominantly toward the right (mean: 2 mm, range: - 11 to 11 mm), anterior (mean: 15 mm, range: 9-21 mm) and caudal (mean: 16 mm, range: 6-24 mm) direction. The mechatronic design of the liver phantom gives the freedom to set direction and amplitude of the motion and was able to mimic the direction of liver motion of one patient. Needle deflection inside the phantom increased from 1.6 to 3.8 mm from the initial expiration state to inspiration.

conclusionsThe developed liver phantom allows for applying different motion patterns and shapes/sizes and thus allows for patient-specific simulation of needle-based interventions. Moreover, it is able to mimic appropriate respiratory motion and needle deflection as observed in patients.

Indexed as

Phantoms, ImagingHumansLiverModels, AnatomicNeedlesOrgan MotionPolyvinyl AlcoholRespiratory MechanicsTomography, X-Ray ComputedPolyvinyl AlcoholInterventional radiologyLiver phantomNeedle deflectionRespiratory motion

Identifiers

PMID31297650
PMCPMC6858400
OpenAlexW2959190839

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.