Evidence map›Paper›PMID 31291373›Full record

Observational studyPloS one2019

Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique.

Hannu Kinnunen, Keijo Häkkinen, Moritz Schumann, Laura Karavirta, Klaas R Westerterp, Heikki Kyröläinen

Open access · goldAbstract readObservational StudyValidation Study
In one paragraph

Observational study in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 2 pooled it
4.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 2 syntheses or guidelines pooled it, 55 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 3 countries.

Hannu KinnunenOptoelectronics and Measurement Techniques Research Group, University of Oulu, Oulu, Finland.ORCID 0000-0001-9190-8708
Keijo HäkkinenBiology of Physical Activity, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland.
Moritz SchumannDepartment of Molecular and Cellular Sports Medicine, German Sport University, Cologne, Germany.
Laura KaravirtaGerontology Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland.
Klaas R WesterterpSchool of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, The Netherlands.
Heikki KyröläinenBiology of Physical Activity, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland.
University of Jyväskylä · FIGerman Sport University Cologne · DEMaastricht University · NLPolar (Finland) · FIUniversity of Oulu · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily energy expenditure, including any change induced by long-term participation in endurance and strength training. Supplemental heart rate monitoring during weekly exercise was also investigated.

methodsA 13-day doubly labeled water (DLW) measurement of total energy expenditure (TEE) was performed twice in healthy male subjects: during two last weeks of a 12-week Control period (n = 15) and during two last weeks of a 12-week combined strength and aerobic Training period (n = 13). Resting energy expenditure was estimated using two equations: one with body weight and age, and another one with fat-free mass. TEE and activity induced energy expenditure (AEE) were determined from motion sensor alone, and from motions sensor combined with heart rate monitor, the latter being worn during exercise only.

resultsWhen body weight and age were used in the calculation of resting energy expenditure, the motion sensor data alone explained 78% and 62% of the variation in TEE assessed by DLW at the end of Control and Training periods, respectively, with a bias of +1.75 (p <.001) and +1.19 MJ/day (p = .002). When exercise heart rate data was added to the model, the combined wearable device approach explained 85% and 70% of the variation in TEE assessed by DLW with a bias of +1.89 and +1.75 MJ/day (p <.001 for both). While significant increases in TEE and AEE were detected by all methods as a result of participation in regular training, motion sensor approach underestimated the change measured by DLW: +1.13±0.66 by DLW, +0.59±0.69 (p = .004) by motion sensor, and +0.98±0.70 MJ/day by combination of motion sensor and heart rate. Use of fat-free mass in the estimation of resting energy expenditure removed the biases between the wearable device estimations and the golden standard reference method of TEE and demonstrated a training-induced increase in resting energy expenditure by +0.18±0.13 MJ/day (p <.001).

conclusionsWrist motion sensor combined with a heart rate monitor during exercise sessions, showed high agreement with the golden standard measurement of daily TEE and its change induced by participation in a long-term training protocol. The positive findings concerning the validity, especially the ability to follow-up the change associated with a lifestyle modification, can be considered significant because they partially determine the feasibility of wearable devices as quantifiers of health-related behavior.

Indexed as

AccelerometryAdultBody WeightDeuterium OxideDrinkingEnergy MetabolismHeart RateHumansLife StyleMaleMonitoring, PhysiologicPhysical Conditioning, HumanPhysical EnduranceWaterWearable Electronic DevicesWristDeuterium OxideWater

Identifiers

PMID31291373
PMCPMC6619827
OpenAlexW2962606778

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.