Evidence map›Paper›PMID 31290286›Full record

ArticleThoracic cancer2019

Efficacy and safety of artificial pneumothorax with position adjustment for CT-guided percutaneous transthoracic microwave ablation of small subpleural lung tumors.

Haipeng Jia, Jie Tian, Bo Liu, Hong Meng, Fengmin Pan, Chunhai Li

Open access · goldAbstract read
In one paragraph

Article in Thoracic cancer, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Identifying symptom clusters and temporal interconnections in patients with lung tumors after CT-guided microwave ablation: A network analysis.Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer · 2024
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Microwave Ablation in Primary Lung Malignancies.Seminars in interventional radiology · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Haipeng JiaDepartment of Radiology, Qilu Hospital of Shandong University, Jinan, China.
Jie TianDepartment of Respiration, Huantai County Hospital of Traditional Chinese Medicine, Zibo, China.
Bo LiuDepartment of Radiology, Qilu Hospital of Shandong University, Jinan, China.
Hong MengDepartment of Radiology, Qilu Hospital of Shandong University, Jinan, China.
Fengmin PanDepartment of Radiology, Qilu Hospital of Shandong University, Jinan, China.
Chunhai LiDepartment of Radiology, Qilu Hospital of Shandong University, Jinan, China.ORCID 0000-0003-4245-7458
Shandong University · CNXintai People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo evaluate the efficacy and safety of artificial pneumothorax with position adjustment for computed tomograpy (CT)-guided percutaneous transthoracic microwave ablation (MWA) of small subpleural lung tumors.

methodsFifty-six patients with small subpleural lung tumors (< 3.0 cm) entered the study and underwent CT-guided MWA with (group I: 24 patients with 24 tumors) or without (group II: 32 patients with 34 tumors) the support of artificial pneumothorax. Follow-up contrast-enhanced CT scans were reviewed. Pain VAS (visual analog scale) scores at, during, and after ablation were compared between the two groups. Technical success, technique efficacy, local tumor control and complications were compared.

resultsCreation of the artificial pneumothorax was achieved for 24/24 (100%) in group I and no complication related to the procedure was observed. Technical success of MWA was achieved for all 58 tumors. Primary efficacy of MWA was achieved in 23 of 24 tumors (95.8%) treated in group I, and 32 of 34 tumors (94.1%) treated in group II (P = 0.771). The 12-month local tumor control was achieved in 87.5% (21/24) in group I compared with 88.2% (30/34) in group II (P = 0.833). Pain VAS scores in group I were significantly decreased after the pneumothorax induction at, during, and after ablation compared with group II (P < 0.05). There was no significant difference in MWA-related complications (P > 0.05).

conclusionArtificial pneumothorax with position adjustment for CT-guided MWA is effective and may be safely applied to small subpleural lung tumors. Artificial pneumothorax is a reliable therapy for pain relief.

Indexed as

AgedCatheter AblationFemaleHumansLung NeoplasmsMaleMiddle AgedPneumothorax, ArtificialArtificial pneumothoraxlung tumorsmicrowave ablationpain relief

Identifiers

PMID31290286
PMCPMC6669918
OpenAlexW2958414540

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.