Evidence map›Paper›PMID 31289997›Full record

ArticleInternational journal of computer assisted radiology and surgery2019

Transbronchial biopsy catheter enhanced by a multisection continuum robot with follow-the-leader motion.

Lenny Dupourqué, Fumitaro Masaki, Yolonda L Colson, Takahisa Kato, Nobuhiko Hata

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. AI co-pilot bronchoscope robot.Nature communications · 2024
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lenny DupourquéÉcole Polytechnique Fédérale de Lausanne (EPFL), Route Cantonale, 1015, Lausanne, Switzerland.
Fumitaro MasakiNational Center for Image Guided Therapy, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St, Boston, MA, 02115, USA.
Yolonda L ColsonDivision of Thoracic Surgery, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St, Boston, MA, 02115, USA.
Takahisa KatoCanon Healthcare Optics Laboratory Boston, 210 Broadway, Cambridge, MA, 02139, USA.
Nobuhiko HataNational Center for Image Guided Therapy, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St, Boston, MA, 02115, USA. hata@bwh.harvard.edu.ORCID http://orcid.org/0000-0002-6818-7700

Funding

Canon USA N/A
6 · The paper itself

Abstract

purposeCurrent manual catheters for transbronchial biopsy in the lung lack a steering ability, which hampers a physician's ability to reach nodules in the peripheral lung. The objective of this paper is to design and build a multisection robot with a follow-the-leader motion and compare the performance of the conventional catheter and our robotic catheter in the right main and right segmental lobar bronchus.

methodsA three-section continuum robot with an outer diameter of 3 mm was developed. Each section includes one anchored wire and two driving wires made of stainless steel. Follow-the-leader control is implemented using a joystick for a physician to control the distal section of the robot, while the subsequent two sections follow the controlled distal section.

resultsThe robotic catheter deviated from the preplanned approach path by less than the manual catheter did (robotic: [Formula: see text] mm and manual: [Formula: see text] mm), with [Formula: see text]. The average force applied to the wall, producing potential trauma to the wall, was less for the robotic catheter ([Formula: see text] N) than for the manual catheter ([Formula: see text] N), [Formula: see text].

conclusionThis study demonstrated an improvement in the maneuverability for the robotic catheter. In addition to a greater aptitude for reaching a peripheral area of the lung, these findings suggest that the designated target in a peripheral area can be reached with less trauma to the bronchi wall.

Indexed as

CathetersBiopsyBronchoscopyEquipment DesignHumansLungPrinting, Three-DimensionalRoboticsBronchoscopyContinuum robotsLung biopsyMultisection robotSurgical robotics

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.