Evidence map›Paper›PMID 31288016›Full record

Trial reportThe Annals of thoracic surgery2020

Radiation Exposure During Transcatheter Valve Replacement: What Cardiac Surgeons Need to Know.

Alejandro Aquino, Ali J Khiabani, Matthew C Henn, Alan Zajarias, Spencer J Melby, Marc Sintek, John Lasala, Puja Kachroo, Eric Novak, Hersh S Maniar

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in The Annals of thoracic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Comprehensive Shielding System Enhances Radiation Protection for Structural Heart Procedures.Journal of the Society for Cardiovascular Angiography & Interventions · 2024
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Alejandro AquinoCardiovascular Division, Department of Medicine, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Ali J KhiabaniDivision of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Matthew C HennDivision of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Alan ZajariasCardiovascular Division, Department of Medicine, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Spencer J MelbyDivision of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Marc SintekCardiovascular Division, Department of Medicine, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
John LasalaCardiovascular Division, Department of Medicine, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Puja KachrooDivision of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Eric NovakCardiovascular Division, Department of Medicine, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri.
Hersh S ManiarDivision of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri. Electronic address: maniarh@wustl.edu.
Barnes-Jewish Hospital · USJewish Hospital · US

Funding

BASIC SCIENCE RESEARCH TRAINING: CARDIOPULMONARY SURGERYT32HL007776 · NHLBI · WASHINGTON UNIVERSITY · PI DAMIANO, RALPH J · 1994 to 2020
$4.6M
NHLBI NIH HHS T32 HL007776
6 · The paper itself

Abstract

backgroundTranscatheter aortic valve replacement (TAVR) and transcatheter mitral valve replacement expose operators to radiation. These procedures differ primarily in whether they are performed via a transfemoral (TF) or an alternative access (AA) approach. This study compared operator radiation exposure during transcatheter valve implantation when performed via a TF vs an AA approach, when performed in a catheterization lab vs a hybrid operating room (OR), and investigated the potential benefit of disposable shielding.

methodsDosimeters were worn during TAVR-TF (n = 50) and TAVR-AA (n = 31) procedures by operators. All TAVR-AA procedures were performed in a hybrid OR and TF procedures were performed in either catheterization labs (n = 16) or a hybrid OR (n = 34). Disposable radiation shielding pads (RADPAD; Worldwide Innovations and Technologies, Inc, Kansas City) or a placebo were added in a randomized, blinded fashion.

resultsTeam radiation exposure was higher after TAVR-AA vs TAVR-TF (median 15.1 mRad [interquartile range: IQR 8.6, 32.4] vs 5.5 mRad [IQR 2.4, 9.8], P < .001). TAVR-TF procedures required the same amount of fluoroscopy time regardless of where they were performed (20.3 ± 7.4 min in hybrid OR vs 19.0 ± 6.4 min in catheterization lab, P = .55). However, radiation exposure for TAVR-TF remained higher when performed in a hybrid OR (median 9.0 mRad [IQR 4.5, 11.9] vs 2.2 mRad [IQR 1.3, 2.8], P < .001). Radiation exposure was greatest for TAVR-AA (median 15.1 mRad [IQR 8.6, 32.4]). The use of RADPAD did not decrease radiation exposure (median 9.0 mRad [IQR 4.5, 14.7] vs 9.4 mRad [IQR 2.8, 19.5], P = .82).

conclusionsProcedures performed in the hybrid OR were associated with higher operator radiation exposure. In comparison with the TF approach, AA cases had the highest levels of operator radiation. This is particularly important in cases of transcatheter mitral valve replacement that can only be done via an AA approach. The use of disposable radiation shielding in this series did not attenuate operator radiation exposure. Radiation shielding within hybrid ORs should be scrutinized in an effort to remain on par with that found within catheterization labs.

Indexed as

Radiation DosageRadiation ProtectionThoracic SurgeryFemoral ArteryHumansOccupational ExposureRadiation ExposureSingle-Blind MethodTranscatheter Aortic Valve Replacement

Identifiers

PMID31288016
PMCPMC6939293
OpenAlexW2953430836

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.