ArticleMedical physics2019
Broadband lung dielectric properties over the ablative temperature range: Experimental measurements and parametric models.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Dielectric properties, thermal properties, blood perfusion rate: which biophysical parameter is the leading source of variability of microwave ablation models in lung?International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2026Article
- An Improved Cole-Cole Model for Characterizing In Vivo Dielectric Properties of Lung Tissue at Different Tide Volumes: An Animal Study.Bioengineering (Basel, Switzerland) · 2025Article
- Application of dielectric properties for identification of normal and malignant gastrointestinal tumors and lymph nodes ex vivo.Physical and engineering sciences in medicine · 2025Article
- [Dielectric properties of tidal volume changes in rabbit lung tissue in the 100 MHz~1 GHz band].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024Article
- Histology-validated electromagnetic characterization of ex-vivo ovine lung tissue for microwave-based medical applications.Scientific reports · 2024Article
- Histology-Validated Dielectric Characterisation of Lung Carcinoma Tissue for Microwave Thermal Ablation Applications.Cancers · 2023Article
- In Vitro Measurement and Mathematical Modeling of Thermally-Induced Injury in Pancreatic Cancer Cells.Cancers · 2023Article
- Temperature dependence of dielectric properties of blood at 10 Hz-100 MHz.Frontiers in physiology · 2022Article
- Efficacy of Lung-Tuned Monopole Antenna for Microwave Ablation: Analytical Solution and Validation in a Ventilator-ControlledIEEE journal of electromagnetics, RF and microwaves in medicine and biology · 2021Article
- [Experimental study on temperature dependence of dielectric properties of biological tissues at 2 450 MHz].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021Article
- Microwave ablation of lung tumors: A probabilistic approach for simulation-based treatment planning.Medical physics · 2021Article
- Broadband Dielectric Properties of Ex Vivo Bovine Liver Tissue Characterized at Ablative Temperatures.IEEE transactions on bio-medical engineering · 2021Article
- Effect of changes in lung physical properties on microwave ablation zone during respiration.Biomedical engineering letters · 2020Article
- [Analysis of dielectric properties of metastatic and non-metastatic lymph nodes from lung cancer surgeries using an open-ended coaxial probe].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeComputational models of microwave tissue ablation are widely used to guide the development of ablation devices, and are increasingly being used for the development of treatment planning and monitoring platforms. Knowledge of temperature-dependent dielectric properties of lung tissue is essential for accurate modeling of microwave ablation (MWA) of the lung.
methodsWe employed the open-ended coaxial probe method, coupled with a custom tissue heating apparatus, to measure dielectric properties of ex vivo porcine and bovine lung tissue at temperatures ranging between 31 and 150
resultsRapid decreases in both relative permittivity and effective conductivity were observed in the temperature range from 94 to 108
conclusionsThe reported dielectric properties of lung tissue, and parametric models which also capture their distribution, will aid the development of computational models of microwave lung ablation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.