Evidence map›Paper›PMID 31284380›Full record

ArticleSensors (Basel, Switzerland)2019

Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications.

Camilo A R Diaz, Arnaldo Gomes Leal-Junior, Letícia M Avellar, Paulo F C Antunes, Maria J Pontes, Carlos A Marques, Anselmo Frizera, Moisés R N Ribeiro

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Camilo A R DiazTelecommunications Laboratory LABTEL, Electrical Engineering Department, Federal University of Espírito Santo, Espírito Santo 29075-910, Brazil. c.rodriguez.2016@ieee.org.ORCID 0000-0001-9657-5076
Arnaldo Gomes Leal-JuniorMechanical Engineering Department, Federal University of Espírito Santo, Espírito Santo 29075-910, Brazil.ORCID 0000-0002-9075-0619
Letícia M AvellarTelecommunications Laboratory LABTEL, Electrical Engineering Department, Federal University of Espírito Santo, Espírito Santo 29075-910, Brazil.
Paulo F C AntunesDepartment of Physics and I3N, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal.ORCID 0000-0001-9129-3539
Maria J PontesTelecommunications Laboratory LABTEL, Electrical Engineering Department, Federal University of Espírito Santo, Espírito Santo 29075-910, Brazil.ORCID 0000-0002-9009-2425
Carlos A MarquesDepartment of Physics and I3N, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal.ORCID 0000-0002-8596-5092
Anselmo FrizeraTelecommunications Laboratory LABTEL, Electrical Engineering Department, Federal University of Espírito Santo, Espírito Santo 29075-910, Brazil.ORCID 0000-0002-0687-3967
Moisés R N RibeiroTelecommunications Laboratory LABTEL, Electrical Engineering Department, Federal University of Espírito Santo, Espírito Santo 29075-910, Brazil.ORCID 0000-0002-9149-2391

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, we report the development of a portable energy-efficient interrogator (Perrogator) for wavelength-based optical sensors. The interrogator is based on a compact solution encompassing a white light source and the spectral convolution between the sensor and a tunable filter, which is acquired by a photodetector, where a microcontroller has two functions: (i) To control the filter tuning and to (ii) acquire the photodetector signal. Then, the data is sent to a single-board computer for further signal processing. Furthermore, the employed single-board computer has a Wi-Fi module, which can be used to send the sensors data to the cloud. The proposed approach resulted in an interrogator with a resolution as high as 3.82 pm (for 15.64 nm sweeping range) and maximum acquisition frequency of about 210 Hz (with lower resolution ~15.30 pm). Perrogator was compared with a commercial fiber Bragg grating (FBG) interrogator for strain measurements and good agreement between both devices was found (1.226 pm/µε for the commercial interrogator and 1.201 pm/µε for the proposed approach with root mean square error of 0.0144 and 0.0153, respectively), where the Perrogator has the additional advantages of lower cost, higher portability and lower energy consumption. In order to demonstrate such advantages in conjunction with the high acquisition frequency allowed us to demonstrate two wearable applications using the proposed interrogation device over FBG and Fabry-Perot interferometer (FPI) sensors. In the first application, an FBG-embedded smart textile for knee angle assessment was used to analyze the gait of a healthy person. Due to the capability of reconstructing the FBG spectra, it was possible to employ a technique based on the FBG wavelength shift and reflectivity to decouple the effects of the bending angle and axial strain on the FBG response. The measurement of the knee angle as well as the estimation of the angular and axial displacements on the grating that can be correlated to the variations of the knee center of rotation were performed. In the second application, a FPI was embedded in a chest band for simultaneous measurement of breath and heart rates, where good agreement (error below 5%) was found with the reference sensors in all analyzed cases.

Indexed as

Signal Processing, Computer-AssistedWearable Electronic DevicesEquipment DesignFiber Optic TechnologyGaitHeart RateHeart Rate DeterminationHumansInterferometryKnee JointRespirationWireless TechnologyFabry-Perot interferometersfiber Bragg gratingsgait analysisinterrogatorswearable applications

Identifiers

PMID31284380
PMCPMC6651577

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.