ArticleActa orthopaedica2019
Cementing of the hip arthroplasty stem increases load-to-failure force: a cadaveric study.
Article in Acta orthopaedica, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Analysis of Bone Loss around Cemented and Biologic Prostheses after Hemiarthroplasty.Disease markers · 2022Trial
- Clinical outcome of periprosthetic femoral fractures: the influence of fracture pattern and patient specific risk factors.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2025Article
- The effect of fixation type on periprosthetic fractures in high-risk patients who have osteoporosis undergoing total joint arthroplasty.Journal of orthopaedics · 2024Article
- Is it reasonable to shorten the length of cemented stems? A finite element analysis and biomechanical experiment.Frontiers in bioengineering and biotechnology · 2023Article
- Analysis of the Effect of Component Ratio Imbalances on Selected Mechanical Properties of Seasoned, Medium Viscosity Bone Cements.Materials (Basel, Switzerland) · 2022Article
- The impact of stem fixation method on Vancouver Type B1 periprosthetic femoral fracture management.SICOT-J · 2022Article
- Biomechanics of a cemented short stem: a comparative in vitro study regarding primary stability and maximum fracture load.Archives of orthopaedic and trauma surgery · 2021Article
- High prevalence and undertreatment of osteoporosis in elderly patients undergoing total hip arthroplasty.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2021Article
- Short stems have lower load at failure than double-wedged stems in a cadaveric cementless fracture model.Bone & joint research · 2019Article
- To cement or not to cement, that is the question in elderly!Joint diseases and related surgeryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose - To date, there is not a single clinical or mechanical study directly comparing a cemented and a cementless version of the same stem. We investigated the load-to-failure force of a cementless and a cemented version of a double tapered stem. Material and methods - 10 femurs from 5 human cadaveric specimens, mean age 74 years (68-79) were extracted. Bone mineral density (BMD) was measured using peripheral quantitative computed tomography. None of the specimens had a compromised quality (average T value 0.0, -1.0 to 1.4). Each specimen from a pair randomly received a cemented or a cementless version of the same stem. A material testing machine was used for lateral load-to-failure test of up to a maximal load of 5.0 kN. Results - Average load-to-failure of the cemented stem was 2.8 kN (2.3-3.2) and 2.2 kN (1.8-2.8) for the cementless stem (p = 0.002). The cemented version of the stem sustained a higher load than its cementless counterpart in all cases. Failure force was not statistically significantly correlated to BMD (p = 0.07). Interpretation - Implanting a cemented version of the stem increases the load-to-failure force by 25%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials