ArticleQuantitative imaging in medicine and surgery2019
Designing visible-light optical coherence tomography towards clinics.
Article in Quantitative imaging in medicine and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed.
- Advances in Wearable Bioimaging.Advanced materials (Deerfield Beach, Fla.) · 2026Review
- Development of an optically emulated computed tomography scanner for college education.Visual computing for industry, biomedicine, and art · 2026Article
- Assessing and monitoring abnormal retinal blood circulation for early detection of pre-structural damage and enhanced diabetic retinopathy staging using non-invasive, high-resolution biophotonic imaging technology.Eye (London, England) · 2025Review
- Integrated visible-light optical coherence tomography and fluorescence scanning laser ophthalmoscopy to image retinal ganglion cell axons.Biomedical optics express · 2025Article
- Visible-light optical coherence tomography and its applications.Neurophotonics · 2025Review
- Photoreceptor Outer Segment Reflectivity With Ultrahigh-Resolution Visible-Light Optical Coherence Tomography in Systemic Hydroxychloroquine Use.Translational vision science & technology · 2025Article
- Review
- Photoreceptor outer segment reflectivity with ultrahigh resolution visible light optical coherence tomography in systemic hydroxychloroquine use.medRxiv : the preprint server for health sciences · 2024Article
- Multiscale imaging of corneal endothelium damage and Rho-kinase inhibitor application in mouse models of acute ocular hypertension.Biomedical optics express · 2024Article
- Hyperreflective Dots in Central Fovea Visualized by a Novel Application of Visible-Light Optical Coherence Tomography.Case reports in ophthalmological medicine · 2024Article
- Hybrid spiral scanning in a double-clad fiber-based handheld confocal scanning light ophthalmoscope.Biomedical optics express · 2023Article
- Visible-light optical coherence tomography platform for the characterization of the skin barrier.Biomedical optics express · 2023Article
- SmartOCT: smartphone-integrated optical coherence tomography.Biomedical optics express · 2023Article
- Simultaneous visible light optical coherence tomography and near infrared OCT angiography in retinal pathologies: A case study.Experimental biology and medicine (Maywood, N.J.) · 2022Article
- The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.Frontiers in medicine · 2022Review
- Global and Regional Damages in Retinal Ganglion Cell Axon Bundles Monitored Non-Invasively by Visible-Light Optical Coherence Tomography Fibergraphy.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2021Article
- Optical Coherence Tomography and Glaucoma.Annual review of vision science · 2021Review
- Advances in Retinal Oximetry.Translational vision science & technology · 2021Review
- Dynamic contrast-enhanced near-infrared spectroscopy using indocyanine green on moderate and severe traumatic brain injury: a prospective observational study.Quantitative imaging in medicine and surgery · 2020Article
- Overview of Ultrasound Detection Technologies for Photoacoustic Imaging.Micromachines · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
backgroundThe capabilities of visible-light optical coherence tomography (vis-OCT) in noninvasive anatomical and functional retinal imaging have been demonstrated by multiple groups in both rodents and healthy human subjects. Translating laboratory prototypes to an integrated clinical-environment-friendly system is required to explore the full potential of vis-OCT in disease management.
methodsWe developed and optimized a portable vis-OCT system for human retinal imaging in clinical settings. We acquired raster- and circular-scan images from both healthy and diseased human eyes.
resultsThe new vis-OCT provided high-quality retinal images of both subjects without any known eye diseases and patients with various retinal diseases, including retinal occlusive disease and diabetic retinopathy (DR) over a broad range of ages.
conclusionsA newly designed vis-OCT system is sufficiently optimized to be suited for routine patients' examinations in clinics. Vis-OCT has the potential to add new anatomical and functional imaging capabilities to ophthalmic clinical care.
Indexed as
Identifiers
What OpenQuestion holds