Evidence map›Paper›PMID 31280637›Full record

ArticleJournal of the American Heart Association2019

Implantable Cardioverter Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices: Utilization Patterns, Related Procedures, and Complications.

Paulino A Alvarez, Brett W Sperry, Antonio L Pérez, Dmitry M Yaranov, Varinder Randhawa, Jacob Luthman, Daniel J Cantillon, Randall C Starling

Abstract read
In one paragraph

Article in Journal of the American Heart Association, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2021
    Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Paulino A Alvarez1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Brett W Sperry1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Antonio L Pérez1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Dmitry M Yaranov1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Varinder Randhawa1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Jacob Luthman1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Daniel J Cantillon1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.
Randall C Starling1 Department of Cardiovascular Medicine Cleveland Clinic Foundation Cleveland OH.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background The effect of implantable cardioverter defibrillators ( ICD ) in patients with continuous flow left ventricular assist devices ( LVAD s) on outcomes has not been evaluated in a randomized clinical trial. Methods and Results This is a retrospective single-center study that included patients who underwent continuous flow LVAD implantation at the Cleveland Clinic between October 2004 and March 2017. Patients were evaluated according to the presence or absence of ICD at the time of LVAD insertion. Among 486 patients in the study cohort, 387 (79.6%) had an ICD before LVAD insertion. Patients with ICD before LVAD were older and had lower use of pre- LVAD inotropes, extracorporeal membrane oxygenation, and mechanical ventilation. There were 81 patients (21.4% of patients with ICD ) who required 93 procedures after LVAD : 74 generator exchanges, 12 lead revisions, and 7 complete system removals because of infection. Of the 99 patients without ICD , 52 (53%) underwent ICD implantation: 29 for primary prevention and 23 for secondary prevention. Patients were followed for a median of 401 (interquartile range 150-966) days. The presence of a pre- LVAD ICD was not associated with mortality in a multivariable model (hazard ratio 1.19, 95% CI 0.73-1.93, P=0.492), nor was the presence of an ICD at any point when analyzed as a time-varying covariate (hazard ratio 1.05, 95% CI 0.50-2.20, P=0.907). Conclusions There is no apparent mortality benefit associated with an ICD in a contemporary cohort of patients with continuous flow LVAD s to balance considerable morbidity involving ICD -related procedures and complications.

Indexed as

MortalityAdultAgedCardiotonic AgentsDefibrillators, ImplantableExtracorporeal Membrane OxygenationFemaleHeart-Assist DevicesHeart FailureHumansMaleMiddle AgedPostoperative ComplicationsPrimary PreventionProportional Hazards ModelsProsthesis ImplantationCardiotonic Agentsimplanted cardioverter defibrillatorinfectionleft ventricular assist device

Identifiers

PMID31280637
PMCPMC6662142

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.