Evidence map›Paper›PMID 31278575›Full record

ArticleEuropean radiology2019

How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT.

André Euler, Natalia Saltybaeva, Hatem Alkadhi

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Recent updates in radioprotection.European radiology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

André EulerInstitute for Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland. and.euler@gmail.com.ORCID http://orcid.org/0000-0001-5019-4585
Natalia SaltybaevaInstitute for Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Hatem AlkadhiInstitute for Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess the impact of patient off-centering on organ dose and image noise for head and thoracoabdominal CT in a pediatric phantom.

methodsAn anthropomorphic phantom simulating a 5-year-old child was used. Semiconductor dosimeters were placed in various cranial and thoracoabdominal organs. Head and thoracoabdominal CT were performed using automatic tube current modulation (ATCM) and default bowtie filters. The phantom was imaged repeatedly at vertical table positions ranging from - 6 to + 6 cm from the 0-position. Tube current time products (TCTP), organ doses, and image noise were recorded. Scatter radiation was measured in the thyroid for head CT. The effect of ATCM and bowtie filters was assessed.

resultsDepending on patient position, organ doses differed up to 22% for the supratentorial brain, 34% for the infratentorial brain, 19% for the eyes, 28% for the lungs, 25% for the stomach, and 22% for the liver compared with those in the 0-position. The relation between position and dose was linear and mainly affected by the bowtie filter in head CT, while it was quadratic and affected by ATCM and bowtie filter in thoracoabdominal CT. It further depended on the relative position of each organ to the isocenter. An inverse relation was found between position and image noise. Scatter radiation was not significantly related to patient positioning (p = 0.21).

conclusionsIn pediatric CT, vertical patient positioning had a substantial impact on radiation dose with differences of up to 34%, depending on the body region and location of each individual organ. KEY POINTS: • Patient off-centering has a substantial impact on organ radiation dose and image noise in pediatric CT. • Impact of patient off-centering on radiation dose and noise differs between head and thoracoabdominal CT. • Differences are caused by both ATCM and bowtie filter in thoracoabdominal CT, but mainly by bowtie filter in head CT.

Indexed as

Phantoms, ImagingRadiation DosageBrainChild, PreschoolHumansPatient PositioningRadiography, ThoracicScattering, RadiationTomography, X-Ray ComputedTumor Protein, Translationally-Controlled 1Tumor Protein, Translationally-Controlled 1ChildMultidetector computed tomographyPhantoms, imagingRadiation dosimetersRadiation exposure

Identifiers

PMID31278575
OpenAlexW2954679397

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.