Event-triggered averaging of electrical impedance tomography (EIT) respiratory waveforms as compared to low-pass filtering for removal of cardiac related impedance changes.

Andrea Coppadoro, Nilde Eronia, Giuseppe Foti, Giacomo Bellani

Abstract read
In one paragraph

Article in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. What is new in respiratory monitoring?Journal of clinical monitoring and computing · 2022
    Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Andrea CoppadoroDepartment of Anesthesia and Intensive Care, San Gerardo Hospital, Monza, Italy.ORCID http://orcid.org/0000-0003-1759-4071
Nilde EroniaDepartment of Anesthesia and Intensive Care, San Gerardo Hospital, Monza, Italy.ORCID http://orcid.org/0000-0002-5350-243X
Giuseppe FotiDepartment of Anesthesia and Intensive Care, San Gerardo Hospital, Monza, Italy.ORCID http://orcid.org/0000-0002-8698-2046
Giacomo BellaniDepartment of Anesthesia and Intensive Care, San Gerardo Hospital, Monza, Italy. giacomo.bellani1@unimib.it.ORCID http://orcid.org/0000-0002-3089-205X

Funding

Università degli Studi di Milano-Bicocca Department funds
6 · The paper itself

Abstract

Electrical impedance tomography (EIT) is used for bedside ventilation monitoring; cardiac related impedance changes represent a source of noise superimposed on the ventilation signal, commonly removed by low-pass filtering (LPF). We investigated if an alternative approach, based on an event-triggered averaging (ETA) process, is more effective at preserving the actual ventilation waveform. Ten paralyzed patients undergoing volume-controlled ventilation were studied; 30 breaths for each patient were identified to compare LPF and ETA. For ETA the identified breaths were temporally aligned on the beginning of inspiration; the values of the thirty curves at each time point were averaged. The analysis was conducted on the global EIT signal and on four ventral-to-dorsal regions of interest. Global tidal variations by ETA resulted higher than LPF (average difference 139 ± 88 arbitrary units, p = 0.004). Both for global and regional waveforms, minimum and maximum EIT slopes were steeper by ETA as compared to LPF (average difference respectively - 57 ± 60 mL/s and 144 ± 96 mL/s for global signal, p < 0.05); ventilator inspiratory peak airflow correlated with maximum slope measured by ETA (r = 0.902, p < 0.001), but not LPF (p = 0.319). Beginning of inspiration identified on the ventilator waveform and on the global EIT signal by ETA occurred simultaneously, (+ 0.04 ± 0.07 s, p = 0.081), while occurred earlier by LPF (- 0.26 ± 0.1 s, p < 0.001). Removal of cardiac related impedance changes by ETA results in a ventilation signal more similar to the waveforms recorded by the ventilator, particularly regarding the slope of impedance changes and time at the minimum values as compared to LPF.

Indexed as

Electric ImpedancePulmonary VentilationRespirationTidal VolumeHumansLungMonitoring, PhysiologicParalysisReproducibility of ResultsRespiration, ArtificialSignal Processing, Computer-AssistedTomographyTomography, X-Ray ComputedCardiac related impedance changes removalEIT filteringElectrical impedance tomographyEvent-triggered averageLow-pass filter

Identifiers

PMID31278546
PMCPMC7223993

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.