Observational studyJournal of clinical monitoring and computing2020

Validity and reliability of pocket-sized ultrasound devices in measurement of optic nerve sheath diameter in ICU patients.

Uğur Özdemir, Meltem Çimen, Tuba Güney, Gül Gürsel

Abstract readObservational Study
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Optic Nerve Sheath Diameter: Which Axis Should Be Measured?Journal of neuroimaging : official journal of the American Society of Neuroimaging
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Uğur ÖzdemirDivision of Critical Care Medicine, Department of Internal Medicine, Gazi University School of Medicine, Ankara, Turkey. ugureuzdemir@gmail.com.ORCID http://orcid.org/0000-0002-8738-3512
Meltem ÇimenDivision of Critical Care Medicine, Department of Anesthesiology, Gazi University School of Medicine, Ankara, Turkey.
Tuba GüneyDivision of Critical Care Medicine, Department of Neurology, Gazi University School of Medicine, Ankara, Turkey.
Gül GürselDepartment of Pulmonary Critical Care Medicine, Gazi University School of Medicine, Ankara, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The measurement of the optic nerve sheath diameter (ONSD) by ultrasonography (USG) is particularly important for intracranial pressure (ICP) monitoring when invasive measurements are not possible or are contraindicated. Standard USG (SUDs) devices can be bulky and may break down the workflow. The validity and reliability of pocket-sized USG devices (PSUDs) compared to SUDs for ONSD measurement has not been investigated, yet. We compared the reliability and validity of PSUDs with SUDs for ONSD measurement. 35 patients were included in the study. ONSD measurements with PSUDs and SUDs were performed by two clinicians as three different measurements in both sagittal and transverse axis of the eye. There was agreement between mean transverse ONSD (mtONSD), mean sagittal ONSD (msONSD), and mean ONSD(mONSD) values measured with each device according to Bland-Altman test (p = 0.166, p = 0.135, p = 0.066, respectively) with no proportional bias (p = 0.544, p = 0.868, p = 0.929, respectively). Intraclass correlation coefficients (ICC) were found to be greater than 0.7 for mtONSD, msONSD, and mONSD values measured by SUD (ICC = 0.790, ICC = 0.817, and ICC = 0.844, respectively). Similarly, for mtONSD, msONSD, and mONSD values measured by PSUD, ICC were found greater than 0.7 (ICC = 0.763, ICC = 0.814, and ICC = 0.843, respectively). There was no statistically significant difference between mtONSD and msONSD (p = 0.441 for SUD and p = 0.893 for PSUD). There was a good correlation between mtONSD and msONSD (r = 0.767 for SUD and r = 0.816 for PSUD). The total variance between three different measurements in the transverse and sagittal axis was ± 0.6 mm. PSUDs can be used with similar validity and reliability as SUDs for ONSD measurement.

Indexed as

AgedCentral Nervous SystemCritical CareFemaleHumansIntensive Care UnitsIntracranial HypertensionIntracranial PressureMaleMiddle AgedMonitoring, IntraoperativeMonitoring, PhysiologicOptic NerveProspective StudiesReproducibility of ResultsROC CurveIntensive care unitIntracranial pressureNoninvasive monitoringOptic nerve sheathPocket-sized ultrasonography deviceRespiratory failure

Identifiers

PMID31278545
PMCPMC7223003

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.