Quantitative phase imaging in common-path cross-referenced holographic microscopy using double-exposure method.

Jaromír Běhal

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Jaromír BěhalDepartment of Optics, Palacký University, 17. listopadu 1192/12, 771 46, Olomouc, Czech Republic. jaromir.behal@upol.cz.ORCID http://orcid.org/0000-0001-5537-4091

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper proposes an optimized implementation of the double-exposure method with emphasis on the uniformity and minimization of the residual phase imperfections in cross-referenced holographic microscopy (CRHM). The quantitative phase images are restored from single-shot cross-referenced holograms, which are separated in the Fourier space and processed to eliminate effects caused by imperfections of the optical path and sample background. CRHM is implemented in a microscope configuration supplemented by a Sagnac interference module providing splitting and shearing of the sample and reference waves. Utilization of the averaging process, which enhances precision of quantitative phase image (QPI) reconstruction, applicable in the methods with a replicated field of view is also presented. The high temporal stability of CRHM is verified in calibration measurements and its application potential demonstrated by a quantitative restoration of the phase resolution target and imaging of biological samples including cheek and sperm cells.