Evidence map›Paper›PMID 31276368›Full record

ArticleAnalytical chemistry2019

Multilayered Microfluidic Paper-Based Devices: Characterization, Modeling, and Perspectives.

Robert B Channon, Michael P Nguyen, Charles S Henry, David S Dandy

Abstract read
In one paragraph

Article in Analytical chemistry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Paper-based pump-free magnetophoresis.Analytical methods : advancing methods and applications · 2020
    Article
  16. Article
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michael P Nguyen

Funding

Low-Cost Versatile Sampler for Personal PM Exposure by MicroenvironmentR33ES024719 · NIEHS · COLORADO STATE UNIVERSITY · PI HENRY, CHARLES S, VOLCKENS, JOHN · 2017 to 2020
$2.1M
A New Paradigm for Workplace Air Sampling and Cost-Effective Exposure AssessmentR01OH010662 · OH · COLORADO STATE UNIVERSITY · PI HENRY, CHARLES S, VOLCKENS, JOHN · 2015 to 2018
$2.0M
ACL HHS R01OH010662NIEHS NIH HHS R33 ES024719NIOSH CDC HHS R01 OH010662
6 · The paper itself

Abstract

Microfluidic paper-based analytical devices (μPADs) are simple but powerful analytical tools that are gaining significant recent attention due to their many advantages over more traditional monitoring tools. These include being inexpensive, portable, pump-free, and having the ability to store reagents. One major limitation of these devices is slow flow rates, which are controlled by capillary action in the hydrophilic pores of cellulosic paper. Recent investigations have advanced the flow rates in μPADs through the generation of a gap or channel between two closely spaced paper sheets. This multilayered format has opened up μPADs to new applications and detection schemes, where large gap sizes (>300 μm) provide at least 169× faster flow rates than single-layer μPADs, but do not conform to established mathematical models for fluid transport in porous materials, such as the classic Lucas-Washburn equation. In the present study, experimental investigations and analytical modeling are applied to elucidate the driving forces behind the rapid flow rates in these devices. We investigate a range of hypotheses for the systems fluid dynamics and establish a theoretical model to predict the flow rate in multilayered μPADs that takes into account viscous dissipation within the paper. Device orientation, sample addition method, and the gap height are found to be critical concerns when modeling the imbibition in multilayered devices.

Indexed as

Lab-On-A-Chip DevicesPaperMicrofluidic Analytical TechniquesModels, Chemical

Identifiers

PMID31276368
PMCPMC7653499

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.