Evidence map›Paper›PMID 31276361›Full record

ArticleACS nano2019

Time-Resolved Digital Immunoassay for Rapid and Sensitive Quantitation of Procalcitonin with Plasmonic Imaging.

Wenwen Jing, Yan Wang, Yunze Yang, Yi Wang, Guangzhong Ma, Shaopeng Wang, Nongjian Tao

Abstract read
In one paragraph

Article in ACS nano, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Label-Free Single-Molecule Immunoassay.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  5. Review
  6. Review
  7. Review
  8. Nanobiosensors for procalcitonin (PCT) analysis.Journal of clinical laboratory analysis · 2024
    Review
  9. Review
  10. Electrochemiluminescence Sensor Based on CTS-MoSFoods (Basel, Switzerland) · 2023
    Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Dynamic single-molecule sensing by actively tuning binding kinetics for ultrasensitive biomarker detection.Proceedings of the National Academy of Sciences of the United States of America · 2022
    Article
  17. Review
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Wenwen JingBiodesign Center for Bioelectronics and Biosensors , Arizona State University , Tempe , Arizona 85287 , United States.ORCID 0000-0003-1038-5509
Yan WangBiodesign Center for Bioelectronics and Biosensors , Arizona State University , Tempe , Arizona 85287 , United States.ORCID 0000-0001-9668-4109
Yunze YangBiodesign Center for Bioelectronics and Biosensors , Arizona State University , Tempe , Arizona 85287 , United States.
Yi WangState Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210093 , China.
Guangzhong MaBiodesign Center for Bioelectronics and Biosensors , Arizona State University , Tempe , Arizona 85287 , United States.
Shaopeng WangBiodesign Center for Bioelectronics and Biosensors , Arizona State University , Tempe , Arizona 85287 , United States.ORCID 0000-0002-2680-0503
Nongjian TaoBiodesign Center for Bioelectronics and Biosensors , Arizona State University , Tempe , Arizona 85287 , United States.

Funding

A Virion-Display Oscillator Array and Detection Platform for Quantification of Transmembrane Protein Binding KineticsR33CA235294 · NCI · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI WANG, SHAOPENG · 2020 to 2022
$1.1M
Measuring small molecule interactions with membrane proteins on single cells via detecting nanometer scale membrane deformationsR01GM124335 · NIGMS · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI WANG, SHAOPENG · 2017 to 2020
$1.1M
NIGMS NIH HHS R01 GM124335
6 · The paper itself

Abstract

Timely diagnosis of acute diseases improves treatment outcomes and saves lives, but it requires fast and precision quantification of biomarkers. Here, we report a time-resolved digital immunoassay based on plasmonic imaging of binding of single nanoparticles to biomarkers captured on a sensor surface. The real-time and high contrast of plasmonic imaging lead to fast and precise counting of the individual biomarkers over a wide dynamic range. We demonstrated the detection principle, evaluated the performance of the method using procalcitonin (PCT) as an example, and achieved a limit of detection of ∼2.8 pg/mL, dynamic range of 4.2-12500 pg/mL, for a total detection time of ∼25 min.

Indexed as

Biosensing TechniquesBiomarkersHumansImmunoassayLimit of DetectionMolecular ImagingNanoparticlesProcalcitoninBiomarkersProcalcitoninplasmonic imagingprocalcitoninrapid and sensitive quantificationsingle nanoparticles analysistime-resolved digital immunoassay

Identifiers

PMID31276361
PMCPMC7008466

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.