Evidence map›Paper›PMID 31273758›Full record

SynthesisThe Cochrane database of systematic reviews2019

Dialysate temperature reduction for intradialytic hypotension for people with chronic kidney disease requiring haemodialysis.

Yasushi Tsujimoto, Hiraku Tsujimoto, Yukihiko Nakata, Yuki Kataoka, Miho Kimachi, Sayaka Shimizu, Tatsuyoshi Ikenoue, Shingo Fukuma, Yosuke Yamamoto, Shunichi Fukuhara

Open access · greenAbstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed, 5 pooled it
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 5 syntheses or guidelines pooled it, 42 citations in OpenAlex.

  1. Guideline
  2. Guideline
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Trial
  8. Trial
  9. Effects of hemodialysis with cooled dialysate on high-sensitivity cardiac troponin I and brain natriuretic peptide.Hemodialysis international. International Symposium on Home Hemodialysis · 2022
    Trial
  10. Review
  11. Review
  12. Review
  13. Article
  14. Article
  15. Acute kidney injury in neurocritical care.Critical care (London, England) · 2023
    Review
  16. Article
  17. Review
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Yasushi TsujimotoDepartment of Healthcare Epidemiology, School of Public Health in the Graduate School of Medicine, Kyoto University, Yoshida Konoe-cho, Sakyo-ku, Kyoto, Japan, 606-8501.
Hiraku Tsujimoto
Yukihiko Nakata
Yuki Kataoka
Miho Kimachi
Sayaka Shimizu
Tatsuyoshi Ikenoue
Shingo Fukuma
Yosuke Yamamoto
Shunichi Fukuhara
Kyoto University · JPHyogo Prefectural Amagasaki General Medical Center · JPShimane University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntradialytic hypotension (IDH) is a common complication of haemodialysis (HD), and a risk factor of cardiovascular morbidity and death. Several clinical studies suggested that reduction of dialysate temperature, such as fixed reduction of dialysate temperature or isothermal dialysate using a biofeedback system, might improve the IDH rate.

objectivesThis review aimed to evaluate the benefits and harms of dialysate temperature reduction for IDH among patients with chronic kidney disease requiring HD, compared with standard dialysate temperature. SEARCH

methodsWe searched Cochrane Kidney and Transplant's Specialised Register up to 14 May 2019 through contact with the Information Specialist using search terms relevant to this review. Studies in the Register are identified through searches of CENTRAL, MEDLINE, EMBASE, conference proceedings, the International Clinical Trials Register (ICTRP) Search Portal, and ClinicalTrials.gov. SELECTION CRITERIA: All randomised controlled trials (RCTs), cross-over RCTs, cluster RCTs and quasi-RCTs were included in the review. DATA COLLECTION AND ANALYSIS: Two authors independently extracted information including participants, interventions, outcomes, methods of the study, and risks of bias. We used a random-effects model to perform quantitative synthesis of the evidence. We assessed the risks of bias for each study using the Cochrane 'Risk of bias' tool. We assessed the certainty of evidence using Grades of Recommendation, Assessment, Development and Evaluation (GRADE). MAIN

resultsWe included 25 studies (712 participants). Three studies were parallel RCTs and the others were cross-over RCTs. Nineteen studies compared fixed reduction of dialysate temperature (below 36°C) and standard dialysate temperature (37°C to 37.5°C). Most studies were of unclear or high risk of bias. Compared with standard dialysate, it is uncertain whether fixed reduction of dialysate temperature improves IDH rate (8 studies, 153 participants: rate ratio 0.52, 95% CI 0.34 to 0.80; very low certainty evidence); however, it might increase the discomfort rate compared with standard dialysate (4 studies, 161 participants: rate ratio 8.31, 95% CI 1.86 to 37.12; very low certainty evidence). There were no reported dropouts due to adverse events. No study reported death, acute coronary syndrome or stroke.Three studies compared isothermal dialysate and thermoneutral dialysate. Isothermal dialysate might improve the IDH rate compared with thermoneutral dialysate (2 studies, 133 participants: rate ratio 0.68, 95% CI 0.60 to 0.76; I AUTHORS'

conclusionsReduction of dialysate temperature may prevent IDH, but the conclusion is uncertain. Larger studies that measure important outcomes for HD patients are required to assess the effect of reduction of dialysate temperature. Six ongoing studies may provide much-needed high quality evidence in the future.

Indexed as

Dialysis SolutionsTemperatureHumansHypotensionRandomized Controlled Trials as TopicRenal DialysisRenal Insufficiency, ChronicDialysis Solutions

Identifiers

PMID31273758
PMCPMC6609546
OpenAlexW2773052780

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.