Evidence map›Paper›PMID 31270704›Full record

ArticleNeurosurgical review2020

Accuracy of cortical bone trajectory screw placement using patient-specific template guide system.

Keitaro Matsukawa, Takashi Kaito, Yuichiro Abe

Abstract read
PubMed Publisher
In one paragraph

Article in Neurosurgical review, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 1 pooled it
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 1 synthesis or guideline pooled it, 34 citations in OpenAlex.

  1. Pooled it
  2. Clinical and radiological evaluation of cortical bone trajectory screw placement using patient-specific 3D templates: a multicentric prospective study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Residual motion of cortical versus pedicle screw constructs after decompression, interbody fusion and cross-link augmentation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Article
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
  18. Accuracy assessment of pedicle screw insertion with patient specific 3D‑printed guides through superimpose CT-analysis in thoracolumbar spinal deformity surgery.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Keitaro MatsukawaDepartment of Orthopaedic Surgery, National Hospital Organization, Murayama Medical Center, 2-37-1 Gakuen, Musashimurayama, Tokyo, 208-0011, Japan. keitaro197897@hotmail.com.ORCID http://orcid.org/0000-0002-1356-5540
Takashi KaitoDepartment of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Yuichiro AbeDepartment of Orthopaedic Surgery, Wajokai Eniwa Hospital, Eniwa, Hokkaido, Japan.
Miwa Hospital · JPMurayama Medical Center · JPThe University of Osaka · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cortical bone trajectory (CBT) can facilitate both minimum invasiveness and strong screw fixation; however, ensuring the ideal cortical trajectory is challenging due to the narrow corridor, necessitating high-level surgical skill. A patient-specific template guide for CBT screw placement may be a promising solution to improve accuracy and safety. Little has been reported on the use of a CBT screw guide in clinical practice. The aim of the present study was to evaluate the accuracy of CBT screw placement using the template guide. This study was a retrospective clinical evaluation of prospectively collected patients. Forty-three consecutively enrolled patients who underwent posterior lumbar spinal fusion using the guide system were included. First, three-dimensional planning of CBT screw placement was performed using computer simulation software. The trajectory was directed in a more anterior position of the vertebral body, compared with the original CBT, and the standard size was set as 5-6 mm in diameter and 40-45 mm in length. Then, screw guides were created for each vertebra preoperatively and used. The safety and accuracy of a total of 198 inserted screws (L1 to L5) were analyzed using postoperative computed tomography by evaluation of pedicle perforation and measurement of screw deviations between the planned and actual screw positions. A total of 193 screws (97.5%) were placed completely inside the pedicle and there was no incidence of neurovascular injuries. The mean screw deviation from the planned trajectory on the coronal plane at the midpoint of the pedicle was 0.62 ± 0.42 mm, and the mean angular deviations in the sagittal and transverse planes were 1.68 ± 1.24° and 1.27 ± 0.77°, respectively. CBT screw placement using a patient-specific template guide was accurate enough for clinical application. This technique could be an effective solution to achieve both correct screw insertion and a reduction of complications.

Indexed as

Bone ScrewsAdultAgedAged, 80 and overComputer SimulationCortical BoneFemaleHumansLumbar VertebraeMaleMiddle AgedPatient SafetyRetrospective StudiesSpinal FusionSpineTomography, X-Ray ComputedAccuracyCortical bone trajectoryLong trajectoryPatient-specific template guidePedicle screwScrew fixation

Identifiers

PMID31270704
OpenAlexW2956028796

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.