Evidence map›Paper›PMID 31269951›Full record

ArticleBMC medical informatics and decision making2019

Design and evaluation of a LIS-based autoverification system for coagulation assays in a core clinical laboratory.

Zhongqing Wang, Cheng Peng, Hui Kang, Xia Fan, Runqing Mu, Liping Zhou, Miao He, Bo Qu

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in BMC medical informatics and decision making, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Automation in the Thrombosis and Hemostasis Laboratory.Methods in molecular biology (Clifton, N.J.) · 2023
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Chronometric vs. Structural Hypercoagulability.Medicina (Kaunas, Lithuania) · 2020
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Zhongqing WangDepartment of Health Statistics, School of Public Health, China Medical University, 77 Puhe Road, Shenyang North New Area, Shenyang, 110122, China.
Cheng PengKey Lens Laboratory of Liaoning Province, Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China.
Hui KangDepartment of Clinical Laboratory, The First Affiliated Hospital of China Medical University, Shenyang, China.
Xia FanDepartment of Clinical Laboratory, The First Affiliated Hospital of China Medical University, Shenyang, China.
Runqing MuDepartment of Clinical Laboratory, The First Affiliated Hospital of China Medical University, Shenyang, China.
Liping ZhouDepartment of Clinical Laboratory, The First Affiliated Hospital of China Medical University, Shenyang, China.
Miao HeDepartment of Information Center, The First Affiliated Hospital of China Medical University, Shenyang, China.
Bo QuDepartment of Health Statistics, School of Public Health, China Medical University, 77 Puhe Road, Shenyang North New Area, Shenyang, 110122, China. qubo6666@163.com.ORCID 0000-0003-2526-9690
China Medical University · CNFirst Hospital of China Medical University · CNFourth Affiliated Hospital of China Medical University · CNShenyang Medical College · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe autoverification system for coagulation consists of a series of rules that allow normal data to be released without manual verification. With new advances in medical informatics, the laboratory information system (LIS) has growing potential for the autoverification, allowing rapid and accurate verification of clinical laboratory tests. The purpose of the study is to develop and evaluate a LIS-based autoverification system for validation and efficiency.

methodsAutoverification decision rules, including quality control, analytical error flag, critical value, limited range check, delta check and logical check, as well as patient's historical information, were integrated into the LIS. Autoverification limited range was constructed based on 5 and 95% percentiles. The four most commonly used coagulation assays, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), and fibrinogen (FBG), were followed by the autoverification protocols. The validation was assessed by the autoverification passing rate, the true-positive cases, the true-negative cases, the false-positive cases, the false-negative cases, the sensitivity and the specificity; the efficiency was evaluated in the turnaround time (TAT).

resultsA total of 157,079 historical test results of coagulation profiles from January 2016 to December 2016 were collected to determine the distribution intervals. The autoverification passing rate was 77.11% (29,165/37,821) based on historical patient data. In the initial test of the autoverification version in June 2017, the overall autoverification passing rate for the whole sample was 78.75% (11,257/14,295), with 892 true-positive cases, 11,257 true-negative cases, 2146 false-positive cases, no false-negative cases, sensitivity of 100% and specificity of 83.99%. After formal implementation of the autoverification system for 6 months, 83,699 samples were assessed. The average overall autoverification passing rate for the whole sample was 78.86% and the 95% confidence interval (CI) of the passing rate was [78.25, 79.59%]. TAT was reduced from 126 min to 101 min, which was statistically significant (P < 0.001, Mann-Whitney U test).

conclusionsThe autoverification system for coagulation assays based on LIS can halt the samples with abnormal values for manual verification, guarantee medical safety, minimize the requirements for manual work, shorten TAT and raise working efficiency.

Indexed as

Blood Coagulation TestsClinical Laboratory Information SystemsClinical Laboratory TechniquesMedical Informatics ApplicationsSafetyHumansSoftware DesignAutoverificationCoagulationLaboratory information systemsMedical safetyTurnaround time

Identifiers

PMID31269951
PMCPMC6609390
OpenAlexW2954363304

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.